Detection of escherichia coli O157:H7 using interdigitated array microelectrode-based immunosensor

被引:1
|
作者
Wang Y.
Wang R. [1 ]
Li Y.
Srinivasan B.
Tung S. [2 ]
Wang H. [3 ]
Slavik M.F. [3 ]
Griffis C.L. [1 ]
机构
[1] Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR
[2] Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR
[3] Department of Poultry Science, University of Arkansas, Fayetteville, AR
来源
Biological Engineering | 2010年 / 2卷 / 02期
关键词
E. coli O157:H7; Immunosensor; Impedance measurement; Interdigitated array microelectrode; Rapid detection;
D O I
10.13031/2013.32718
中图分类号
学科分类号
摘要
In this study, a label-free interdigitated array (IDA) microelectrode-based immunosensor was designed and tested for rapid and sensitive detection of E. coli O157:H7. The surface of gold IDA microelectrodes (25 pairs of fingers with 700 μm length and 10 μm width and space) was modified with protein A and further immobilized with polyclonal antibodies against E. coli O157:H7. A 20 μL sample containing E. coli O157:H7 in 0.01 M phosphate buffered saline (PBS) at pH 7.4 was dropped on the surface of the modified microelectrodes and incubated for 2 h at room temperature. After the target bacteria were captured by the antibodies immobilized on the microelectrode, a wash with PBS was applied to rinse off all unbound parts of the sample. Finally, the impedance, both magnitude and phase angle, was measured over a broad frequency range from 1 Hz to 1 MHz. The results showed that the impedance in a frequency range of 1 Hz to 1 kHz increased with the increasing number of E. coli O157:H7 in a range from 80 to 2 × 105 cells per 20 μL. A linear relationship between the magnitude of measured impedance and the log number of cells was determined at the frequency of 1 kHz. This biosensing method was able to detect as few as 80 cells of E. coli O157:H7 within 2 h. The specificity of the immunosensor was validated using five non-target bacteria, and none of them generated detectable signals. The application of the immunosensor for food safety was demonstrated with food samples including chicken carcasses, ground beef, and fresh cut broccoli inoculated with E. coli O157:H7. At the same time, the capture of E. coli O157:H7 cells on the microelectrode surface was confirmed using atomic force microscopy. © 2010 ASABE ISSN 1934-2799.
引用
收藏
页码:49 / 62
页数:13
相关论文
共 50 条
  • [41] QUARTZ CRYSTAL AU ELECTRODE-BASED ELECTROCHEMICAL IMMUNOSENSOR FOR RAPID DETECTION OF ESCHERICHIA COLI O157:H7
    Li, D.
    Xu, K.
    Wang, J.
    Ye, Z.
    Ying, Y.
    Li, Y.
    TRANSACTIONS OF THE ASABE, 2008, 51 (05) : 1847 - 1852
  • [42] Quartz crystal Au electrode-based electrochemical immunosensor for rapid detection of Escherichia coli O157:H7
    College of Biosystems Engineering and Food Science, Zhejiang University, 268 Kaixuan Road, Hangzhou 310029, China
    Trans. ASABE, 2008, 5 (1847-1852):
  • [43] A homogeneous magnetic bead-based impedance immunosensor for highly sensitive detection of Escherichia coli O157:H7
    Wang, Shujun
    Sun, Chongyun
    Hu, Qiushi
    Li, Shuang
    Wang, Chengbin
    Wang, Peng
    Zhou, Lei
    BIOCHEMICAL ENGINEERING JOURNAL, 2020, 156 (156)
  • [44] A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection
    Abu Bakar, M. H.
    Ibrahim, M. H.
    Kassim, N. M.
    Mohammad, A. B.
    2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 51 - 54
  • [45] Electrochemical biosensors for rapid detection of Escherichia coli O157:H7
    Xu, Meng
    Wang, Ronghui
    Li, Yanbin
    TALANTA, 2017, 162 : 511 - 522
  • [46] Carbon dots and covalent organic frameworks based FRET immunosensor for sensitive detection of Escherichia coli O157:H7
    Wang, Sunli
    Liang, Nini
    Hu, Xuetao
    Li, Wenting
    Guo, Ziang
    Zhang, Xinai
    Huang, Xiaowei
    Li, Zhihua
    Zou, Xiaobo
    Shi, Jiyong
    FOOD CHEMISTRY, 2024, 447
  • [47] Detection of Escherichia coli O157:H7 in the beef marketed in Malaysia
    Radu, S
    Mutalib, SA
    Rusul, G
    Ahmad, Z
    Morigaki, T
    Asai, N
    Kim, YB
    Okuda, J
    Nishibuchi, M
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1998, 64 (03) : 1153 - 1156
  • [48] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Barbora Vidová
    Eva Tóthová
    Ľuboslav Blahut
    Viera Horváthová
    Andrej Godány
    Biologia, 2011, 66 : 401 - 405
  • [49] Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection
    Muhammad-Tahir, Z
    Alocilja, EC
    IEEE SENSORS JOURNAL, 2003, 3 (04) : 345 - 351
  • [50] Detection and characterization of the fimA gene of Escherichia coli O157:H7
    Li, BG
    Koch, WH
    Cebula, TA
    MOLECULAR AND CELLULAR PROBES, 1997, 11 (06) : 397 - 406