Development of on-line monitoring system for high voltage vacuum circuit breaker and fault diagnosis

被引:0
|
作者
Zeng, Qingjun [1 ]
Lin, Yanxia [1 ]
机构
[1] School of Electronics and Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
来源
Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition) | 2009年 / 39卷 / SUPPL. 2期
关键词
Voltage measurement - Digital signal processing - Digital signal processors - Electric circuit breakers - Timing circuits - Electric fault currents - Fault detection - Computer programming languages;
D O I
暂无
中图分类号
学科分类号
摘要
In order to improve the reliability of circuit breaker, an on-line monitoring system for high voltage vacuum circuit breaker based on DSP(digital signal processor) and LabVIEW is developed. The system mainly include three components, such as upper and lower links and sensors. The module of scene monitor is composed of sensors and lower link, installed in the circuit breaker. The lower link takes TMS320F2812DSP as the core. The signals of mechanical characteristics acquired by DSP are transmited to host PC through CAN bus for further analysis and processing. The software takes LabVIEW as developing platform and realize the function of storing, displaying and analyzing metrical data. Test results show that the designed on-line monitoring system can reflect the real-time mechanical running condition of the vacuum circuit breaker. It is friendly to use, and it has complete funtion and high reliability. Also, the desired functionality is achieved.
引用
收藏
页码:42 / 48
相关论文
共 50 条
  • [1] Design of High Voltage Vacuum Circuit Breaker's On-line Monitoring and Fault Diagnosis System
    Mei Fei
    Zhu Kedong
    Zheng Jianyong
    Zhu Meng
    PROCEEDINGS OF 2016 IEEE ADVANCED INFORMATION MANAGEMENT, COMMUNICATES, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IMCEC 2016), 2016, : 408 - 413
  • [2] Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker
    Mei Fei
    Mei Jun
    Zheng Jianyong
    Wang Yiping
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2013, 8 (04) : 813 - 823
  • [3] On-line hybrid fault diagnosis method for high voltage circuit breaker
    Mei Fei
    Pan Yi
    Zhu Kedong
    Zheng Jianyong
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2017, 33 (05) : 2763 - 2774
  • [4] On-line Monitoring System for Mechanical Characteristics of Vacuum Circuit Breaker
    Liu, Guixin
    Tian, Yu
    Pan, Zhaoyang
    Dong, Enyuan
    Zou, Jiyan
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1100 - 1104
  • [5] On-line monitoring of mechanical characteristics of high voltage circuit breaker
    Wen, Xue
    Tang, Ju
    Sun, Caixin
    Gaodianya Jishu/High Voltage Engineering, 1997, 23 (01): : 40 - 42
  • [6] On-line measurement of high voltage breaking current for vacuum circuit breaker
    Tsinghua University, Beijing 100084, China
    不详
    Dianli Xitong Zidonghue, 2007, 3 (91-94):
  • [7] Novel method of on-line monitoring vacuum for vacuum circuit breaker
    Zhenjiang Tailifeng Electronic Co. Ltd., Zhenjiang 212021, China
    Dianli Xitong Zidonghue, 2006, 11 (49-51+60):
  • [8] Fault diagnosis of high voltage vacuum circuit breaker based on current signal
    Zeng, Qing-Jun
    Kang, An-Ming
    Lin, Yan-Xia
    Nanjing Li Gong Daxue Xuebao/Journal of Nanjing University of Science and Technology, 2011, 35 (SUPPL. 2): : 108 - 114
  • [9] Study on the on-line monitoring system for contactor's temperature of vacuum circuit breaker
    Liu, Ming-Guang
    Gao, Shi-Qin
    Xu, Xin-She
    Niu, Cheng-Xin
    Kong, Zhong-Qiu
    2001, Science Press (24):
  • [10] Research and Realization of On-line Monitoring System for High Voltage Circuit Breaker Based on ZigBee Technology
    Hu, Zhenfeng
    Geng, Xin
    Xiao, Jin
    Hu, Xiaoguang
    2009 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-3, 2009, : 190 - 195