Research progress of polyethyleneimine crosslinked polymer gel system in water-drive reservoirs

被引:0
|
作者
Wang K. [1 ]
Luo M. [1 ]
Li M. [1 ]
Huang F. [2 ]
Pu C. [1 ]
Pu J. [3 ]
Fan Q. [1 ]
机构
[1] College of Petroleum Engineering, China University of Petroleum (East China), Shandong, Qingdao
[2] School of Petroleum Engineering and Environmental Engineering, Yan’an University, Shaanxi, Yan’an
[3] College of Carbon Neutral Energy, China University of Petroleum (Beijing), Beijing
来源
Huagong Jinzhan/Chemical Industry and Engineering Progress | 2024年 / 43卷 / 03期
关键词
conformance control; crosslinker; gels; polyethyleneimine(PEI); polymers; viscosity; water shutoff;
D O I
10.16085/j.issn.1000-6613.2023-0376
中图分类号
学科分类号
摘要
Polyethyleneimine (PEI) is an environment-friendly and low toxic material. PEI and polymer crosslinked gel system has the advantages of controllable gelation time, high strength of mature gel, high-temperature resistance, long-time stability, and almost unaffected by minerals of reservoir. This paper reviewed the research of various polymer gel systems with PEI as crosslinker. The crosslinking mechanism and the characteristics of those gel systems were clarified. The influence of various factors on the gel system was analyzed. And, the methods to improve the gel performance and successful filed trial were listed, the methods to improve the crosslinking activity of gel system were emphatically analyzed. Finally, it was pointed out that polyacrylamide(PAM)/PEI gel system, as an environment-friendly system, had great application prospects in conformance control and water shutoff of medium and low temperature reservoirs, and it was suggested that the method and the corresponding mechanism of improving the crosslinking efficiency of PAM/PEI system should be studied more extensively and deeply to reduce the loading amount of polymer and crosslinker, and provided a theoretical basis and experimental basis for the promotion and application of this system. © 2024 Chemical Industry Press Co., Ltd.. All rights reserved.
引用
收藏
页码:1506 / 1523
页数:17
相关论文
共 95 条
  • [1] LI Yikun, LI Yuxiang, PENG Yang, Et al., Water shutoff and profile control in China over 60 years, Oil Drilling & Production Technology, 41, 6, pp. 773-787, (2019)
  • [2] WANG Xiang, GUO Jixiang, CHEN Jinmei, Research progress of deep profile control technology and its application, Oilfield Chemistry, 37, 4, pp. 738-744, (2020)
  • [3] ZHU Daoyi, BAI Baojun, HOU Jirui, Polymer gel systems for water management in high-temperature petroleum reservoirs: A chemical review, Energy & Fuels, 31, 12, pp. 13063-13087, (2017)
  • [4] SERIGHT R S., Gel propagation through fractures, SPE Production & Facilities, 16, 4, pp. 225-231, (2001)
  • [5] BRYANT Steven L, BARTOSEK Martin, LOCKHART Thomas P, Et al., Polymer gelants for high temperature water shutoff applications, SPE Journal, 2, 4, pp. 447-454, (1997)
  • [6] BARTOSEK Martin, MENNELLA Aniello, LOCKHART T P, Et al., Polymer gels for conformance treatments: Propagation of Cr(III) crosslinking complexes in porous media, Proceedings - SPE/DEO Ninth Symposium on Improved Oil Recovery, 2, pp. 505-517, (1994)
  • [7] ALBONICO Paola, BARTOSEK Martin, MALANDRINO Alberto, Et al., Studies on phenol-formaldehyde crosslinked polymer gels in bulk and in porous media, All Days, (1995)
  • [8] WANG Kai, LUO Mingliang, LI Mingzhong, Et al., Optimization of hydrolyzed polyacrylamide/chromium (Ⅲ)-acetate gel-plugging process after preflush crosslinker in fractured extralow permeability reservoir at moderate temperature, SPE Journal, 28, 2, pp. 683-696, (2023)
  • [9] GANGULY S, WILLHITE G P, GREEN D W, Et al., The effect of fluid leakoff on gel placement and gel stability in fractures, SPE Journal, 7, 3, pp. 309-315, (2002)
  • [10] REDDY B R, EOFF Larry S, CRESPO Freddy, Et al., Recent advances in organically crosslinked conformance polymer systems, All Days, (2013)