Influence of ambient conditions, refrigerant charge and condenser fan speed on thermal performance of an air source heat pump for drying fruits

被引:0
|
作者
20171403535619
机构
来源
(1) Department of Mechanical Engineering, Mechatronics and Industrial Design, Tshwane University of Technology, Private Bag X680, Pretoria; 0001, South Africa | 1600年 / Chemours; Daikin Industries, Ltd.; Denso Corporation; et al.; Fuji Electric Co., Ltd.; Fujitsu General Limited卷 / International Institute of Refrigeration期
关键词
Experimental optimization of an air source heat pump for drying fruits was conducted by varying the refrigerant charge; condenser fan speed and the ambient conditions to obtain the optimum operating parameters of the heat pump and the dryer as a single integrated unit. The results showed that; the coefficient of performance (COP) of the overall system and the cycle increased with the increase of condenser fan speed; ambient temperature and refrigerant charge. However; at high refrigerant charge and speed of the condenser fan; the COP of the overall system decreased because of the decreased heating capacity possible due to accumulation of refrigerant in the condenser and increased fan power consumption; respectively. For the developed system; the optimum refrigerant charge was observed to be 1650 grams and 840 rpm of condenser fan speed (60% of the full speed) and the appropriate operating ambient temperature of 20 °C. At this point; the COP of the overall system and the heat pump cycle were 3.75 and 5.20; respectively;
D O I
暂无
中图分类号
学科分类号
摘要
126882
引用
收藏
相关论文
共 50 条
  • [1] Influence of Refrigerant Properties and Charge Amount on Performance of Reciprocating Compressor in Air Source Heat Pump
    Afshari, Faraz
    Comakli, Omer
    Adiguzel, Nesrin
    Zavaragh, Hadi Ghasemi
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (01)
  • [2] Study on the influence of refrigerant charge on performance of heat pump units
    Zhao Yuqing
    Dai Yun
    Gao Jianling
    Liu Qingqing
    2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199
  • [3] Evaluation of the impacts of refrigerant charge on air conditioner and heat pump performance
    Kim, Woohyun
    Braun, James E.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (07): : 1805 - 1814
  • [4] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Li Kang
    Lan Jiao
    Zhou Guoliang
    Tang Qitian
    Cheng Qia
    Fang Yidong
    Su Lin
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (02) : 294 - 305
  • [5] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Kang Li
    Jiao Lan
    Guoliang Zhou
    Qitian Tang
    Qia Cheng
    Yidong Fang
    Lin Su
    Journal of Thermal Science, 2019, 28 : 294 - 305
  • [6] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    LI Kang
    LAN Jiao
    ZHOU Guoliang
    TANG Qitian
    CHENG Qia
    FANG Yidong
    SU Lin
    JournalofThermalScience, 2019, 28 (02) : 294 - 305
  • [7] INFLUENCE OF REFRIGERANT CHOICE ON PERFORMANCE OF AIR-SOURCE HEAT PUMPS
    Pearson, S. Forbes
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 51 - 58
  • [8] Effects of component arrangement and ambient and drying conditions on the performance of heat pump dryers
    Saensabai, P
    Prasertsan, S
    DRYING TECHNOLOGY, 2003, 21 (01) : 103 - 127
  • [9] Performance analysis of an air-source heat pump using an immersed water condenser
    Ji J.
    Fu H.
    He H.
    Pei G.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (2): : 234 - 245
  • [10] Improving cold climate air-source heat pump performance with refrigerant mixtures
    Hakkaki-Fard, Ali
    Aidoun, Zine
    Ouzzane, Mohamed
    APPLIED THERMAL ENGINEERING, 2015, 78 : 695 - 703