Current control strategy of three-phase series resonant inverter under unbalanced load

被引:0
|
作者
Yu, Yuesen [1 ]
Nian, Changchun [1 ]
Xie, Guangqing [1 ]
Liu, Zhiyuan [1 ]
Jia, Na [1 ]
Xia, Chenyang [1 ]
Wu, Xiaojie [1 ]
机构
[1] China University of Mining and Technology, Xuzhou,221116, China
关键词
Electric current control;
D O I
暂无
中图分类号
学科分类号
摘要
Aimed at the power transmission control for three-phase wireless power transfer system, three-phase wireless power transfer system adopted the series resonant inverter in primary side is analyzed detailedly. Aimed at the difficulty on power control caused by three-phase unbalanced current under unbalanced load, based on that the PR controller can realize the tracking control of sinusoidal signal for a certain frequency, balancing control is conducted for primary three-phase current by adopting PR controller in αβ coordinate system. The results of simulation and experiment indicate that PR controller can realize the tracking control of the load current of three-phase series resonant inverter which can solve the unbalance of three-phase and provide the basis for the power control of three-phase wireless power transfer system.
引用
收藏
页码:49 / 53
相关论文
共 50 条
  • [1] A Novel Control Strategy for Three-phase Inverter with Unbalanced Load
    Luo Yaohua
    Duan Xiaoli
    Meng Fanrong
    You Jiang
    2011 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SYSTEMS SCIENCE AND ENGINEERING (ICESSE 2011), VOL 2, 2011, : 571 - 578
  • [2] A double-loop control strategy for three-phase inverter with unbalanced load
    Wang, Hengli
    Fu, Lijun
    Xiao, Fei
    Jie, Guisheng
    Zhu, Wei
    Dianwang Jishu/Power System Technology, 2013, 37 (02): : 398 - 404
  • [4] Study on unbalanced load of three-phase inverter
    Cao, Tai-Qiang
    Qi, Qiang
    Wang, Jun
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2012, 16 (04): : 50 - 55
  • [5] Research on three-phase inverter with unbalanced load
    Li, P
    Dan, B
    Yong, K
    Jian, C
    APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 128 - 133
  • [6] Control of a Three-Phase Inverter under Unbalanced Grid Conditions
    Chowdhury, Vikram Roy
    Mukherjee, Subhajyoti
    Shamsi, Pourya
    Ferdowsi, Mehdi
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 2909 - 2913
  • [7] Improved Sequence Decomposition Control Strategy for Three-phase Four-leg Inverter with Unbalanced Load
    Zhou, Xiao
    Jin, Xinmin
    Tang, Fen
    Tong, Yibin
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (08): : 2504 - 2512
  • [8] Sequence-decoupled resonant control of three-phase grid-interfacing inverter for local voltage support under unbalanced load
    Zhang, Y.
    Roes, M. G. L.
    Hendrix, M. A. M.
    Duarte, J. L.
    Huisman, H.
    Lomonova, E. A.
    2018 20TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'18 ECCE EUROPE), 2018,
  • [9] A New Resonant Control Strategy for Three-phase Grid Connected Inverter
    Ma W.
    Ouyang S.
    Yang L.
    Dianwang Jishu/Power System Technology, 2019, 43 (08): : 2884 - 2891
  • [10] An individual sequencing control strategy for three-phase four-leg inverter under unbalanced loads
    Jiang, Hanzhou
    Pan, Huan
    Shang, Bin
    ENERGY REPORTS, 2023, 9 : 256 - 266