Continuous monitoring experiment of soil radon levels using a semiconductor-based measuring instrument

被引:0
|
作者
Dong, Xianglong [1 ,2 ]
Ma, Ziji [1 ,3 ]
Ding, Weicheng [4 ]
Jiang, Zhiwen [1 ]
Wang, Qi [1 ]
Luo, Xi [2 ]
Xu, WeiFu [5 ]
机构
[1] Hunan Univ, Changsha 410082, Peoples R China
[2] Hunan Commun Polytech, Changsha 410132, Peoples R China
[3] Hunan Univ, Guangdong Hong Kong Macao Greater Bay Area Innovat, Hong Kong 511340, Guangdong, Peoples R China
[4] Chengdu Univ Technol, Chengdu 610059, Peoples R China
[5] Southwest Jiaotong Univ, Chengdu 610031, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil radon measurement; 222Rn; Alpha particle; Radon continuous monitoring; Semiconductor detector; Radon measuring instrument;
D O I
10.1016/j.nima.2024.169885
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Soil radon measurement is crucial for environmental safety, public health, and earth science research. Despite significant advancements in the development of radon measurement instruments and methods, there is still a lack of instruments for continuous soil radon monitoring. Therefore, we have developed a continuous radon measurement instrument and designed a corresponding field installation method. This instrument uses a gold- silicon surface barrier semiconductor electrostatic method to measure radon exhalation concentration from the soil and achieves automatic sampling via natural air diffusion. It operates on solar power, is easy to install, and supports both wireless and wired communication. Multiple instruments have been continuously tested in the field for more than a year, showing consistent data among adjacent instruments and the ability to reveal the fluctuation patterns of soil radon. However, practical applications have encountered some challenges, such as data noise and the impact of condensate water on the detector surface.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Measuring Radon Concentration Levels in Fertilizers using CR-39 Detector
    Aswood, Murtadha Sh
    Jaafar, Mohamad S.
    Bauk, Sabar
    MICRO/NANO SCIENCE AND ENGINEERING, 2014, 925 : 610 - +
  • [32] Design and fabrication of optical microcavities using III-V Semiconductor-based MOEMS
    Viktorovitch, P
    Leclercq, JL
    Goutain, E
    Rondi, D
    MOEMS AND MINIATURIZED SYSTEMS, 2000, 4178 : 298 - 309
  • [33] Determination of Asymmetric Dimethylarginine by Using Organic Semiconductor-Based Molecularly Imprinted Polymer Film
    Malyshev, Valerii
    Michota-Kaminska, Agnieszka
    Shao, Shuai
    D'Souza, Francis
    Noworyta, Krzysztof
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2018, 7 (07) : Q3189 - Q3195
  • [34] Characterization of Semiconductor-Based Optical Frequency Comb Sources Using Generalized Multiheterodyne Detection
    Klee, Anthony
    Davila-Rodriguez, Josue
    Williams, Charles
    Delfyett, Peter J.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2013, 19 (04)
  • [35] MEASUREMENT OF MICROSCALE PATCHINESS IN A TURBULENT AQUATIC ODOR PLUME USING A SEMICONDUCTOR-BASED MICROPROBE
    MOORE, PA
    ZIMMERFAUST, RK
    BEMENT, SL
    WEISSBURG, MJ
    PARRISH, JM
    GERHARDT, GA
    BIOLOGICAL BULLETIN, 1992, 183 (01): : 138 - 142
  • [36] Development of soil moisture content measuring instrument based on GPS position
    Qiu, Zheng-Jun
    He, Yong
    Ge, Xiao-Feng
    Feng, Lei
    Zhejiang Daxue Xuebao (Nongye yu Shengming Kexue Ban)/Journal of the Zhejiang University - Agriculture and Life Science, 2003, 29 (02):
  • [37] Seasonal variations in soil radon emanation: long-term continuous monitoring in light of seismicity
    Sedat İnan
    Alican Kop
    Hasan Çetin
    Furkan Kulak
    Zümer Pabuçcu
    Cemil Seyis
    Semih Ergintav
    Onur Tan
    Ruhi Saatçılar
    M. Nuri Bodur
    Natural Hazards, 2012, 62 : 575 - 591
  • [38] Seasonal variations in soil radon emanation: long-term continuous monitoring in light of seismicity
    Inan, Sedat
    Kop, Alican
    Cetin, Hasan
    Kulak, Furkan
    Pabuccu, Zumer
    Seyis, Cemil
    Ergintav, Semih
    Tan, Onur
    Saatcilar, Ruhi
    Bodur, M. Nuri
    NATURAL HAZARDS, 2012, 62 (02) : 575 - 591
  • [39] A continuous radon monitoring system based on a solid-state silicon detector
    Pena-Eguiluz, R.
    Garcia-Hernandez, J. M.
    Ramirez-Jimenez, F. J.
    JOURNAL OF APPLIED RESEARCH AND TECHNOLOGY, 2007, 5 (01) : 3 - 9
  • [40] An action-research based instrument for monitoring continuous quality improvement
    Prybutok, VR
    Ramasesh, R
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2005, 166 (02) : 293 - 309