Hand-eye calibration of welding robot based on the constraint of spatial line

被引:0
作者
Zheng J. [1 ]
Zhang K. [1 ]
Luo Z. [1 ]
Wang Z. [1 ]
机构
[1] Shanghai Key Laboratory of Materials Laser Processing and Modification, Shanghai Jiao Tong University, Shanghai
来源
Hanjie Xuebao/Transactions of the China Welding Institution | 2018年 / 39卷 / 08期
关键词
Hand-eye calibration; Line structured light sensor; Linear constraint;
D O I
10.12073/j.hjxb.2018390211
中图分类号
学科分类号
摘要
The calibration of vision sensor and welding robot is essential in the application of intelligent robot. In this article, to solve the hand-eye calibration of a welding robot holding a line structured light sensor, a method based on a spatial straight line is proposed. Firstly, the robot is required to manipulate randomly its end-effector so that the light plane projected by the line structured light sensor could intersect the calibration template at different configurations. Then the characteristic point extraction algorithm is used to extract the intersection point of the line structure light and the straight line. And a nonlinear optimization model is established based on the linear constraint. Finally, the penalty function method and the advanced Powell algorithm are used to solve the position and direction parameters simultaneously. Based on the above method, a series of experiments is carried out and the experimental results show that the method is versatile and suitable for on-site calibration, which effectively improves the calibration accuracy. The calibration accuracy is within 0.2 mm. © 2018, Editorial Board of Transactions of the China Welding Institution, Magazine Agency Welding. All right reserved.
引用
收藏
页码:108 / 113
页数:5
相关论文
共 8 条
[1]  
Besl P.J., Active, optical range imaging sensors, Machine Vision and Applications, 1, 2, pp. 127-152, (1988)
[2]  
Che C., Ni J., A ball-target-based extrinsic calibration technique for high-accuracy 3-D metrology using off-the-shelf laser-stripe sensors, Precision Engineering, 24, 3, pp. 210-219, (2000)
[3]  
Santolaria J., Pastor J., Brosed F., Et al., A one-step intrinsic and extrinsic calibration method for laser line scanner operation in coordinate measuring machines, Measurement Science and Technology, 20, 4, (2009)
[4]  
Wang S., Du D., Zhang W., Et al., Hand-eye calibration for the robot by measuring a fixed point from different poses, Journal-Tsinghua Universlty Science and Technology, 47, 2, pp. 165-168, (2007)
[5]  
Wu L., Yang X., Lan S., Et al., Robotic TCF calibration based on a planar template, Robot, 34, 1, pp. 98-103, (2012)
[6]  
Shiu Y.C., Ahmad S., Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form AX= XB, IEEE Transactions on Robotics and Automation, 5, 1, pp. 16-29, (1989)
[7]  
Tsai R.Y., Lenz R.K., A new technique for fully autonomous and efficient 3D robotics hand/eye calibration, IEEE Transactions on Robotics and Automation, 5, 3, pp. 345-358, (1989)
[8]  
Yin S., Guo Y., Ren Y., Et al., A novel TCF calibration method for robotic visual measurement system, Optik-International Journal for Light and Electron Optics, 125, 23, pp. 6920-6925, (2014)