Single-line-to-ground fault location in the compensated distribution network

被引:1
|
作者
Xu, B. [1 ,2 ,3 ,4 ]
Cai, X. [1 ,2 ,3 ,4 ]
Zhu, M.J. [1 ,2 ,3 ,4 ]
Qin, H. [1 ,2 ,3 ,4 ]
Xi, D.M. [1 ,2 ,3 ,4 ]
机构
[1] Wind Power Research Center, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
[2] Jinshan Power Supply Company, SMEPC, Shanghai, China
[3] Shinan Power Supply Company, SMEPC, Shanghai, China
[4] School of Electric Power, Inner Mongolia University of Technology, Hohhot, China
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Electric power distribution - Fast Fourier transforms - Signal generators - Electric grounding - Location
引用
收藏
页码:449 / 458
相关论文
共 50 条
  • [21] Study on fault location of single-phase-to-ground for distribution network
    Zhang, Li
    Yang, Xiuyuan
    Ren, Junling
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1101 - 1106
  • [22] Stator single-line-to-ground fault protection for powerformers based on HSGC and CNN
    Liu, Xiaohan
    Wang, Yuanyuan
    Luo, Xiaomin
    Cao, Chengjun
    Li, Wei
    Wang, Buming
    Wang, Jiabao
    Wang, Yin
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [23] A novel one-terminal single-line-to-ground fault location algorithm in transmission line using post-single-phase-trip data
    Geng, Jianzhao
    Wang, Bin
    Dong, Xinzhou
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (16): : 184 - 193
  • [24] Zero-sequence voltage trajectory analysis for unbalanced distribution networks on single-line-to-ground fault condition
    Meng, Jun
    Wang, Wen
    Tang, Xin
    Xu, Xianyong
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 161 : 17 - 25
  • [25] SINGLE-LINE-TO-GROUND FAULT TEST OF A 3-PHASE SUPERCONDUCTING FAULT CURRENT LIMITING REACTOR
    SHIMIZU, S
    KADO, H
    URIU, Y
    ISHIGOHKA, T
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (01) : 442 - 445
  • [26] Faulty Phase Detection Method Under Single-Line-to-Ground Fault Considering Distributed Parameters Asymmetry and Line Impedance in Distribution Networks
    Wang, Wen
    Gao, Xiong
    Fan, Bishuang
    Zeng, Xiangjun
    Yao, Ganzhou
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 1513 - 1522
  • [27] Power distribution network ground fault location algorithm using on-line detectors
    Yi, Guiye
    Yang, Xuechang
    Wu, Zhensheng
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2000, 40 (07): : 35 - 38
  • [28] The Identification of Single-Line-to-Ground Fault in Neutral Un-effectively Earthed System
    Dong, Fengxiang
    Tang, Chaoguo
    Yuan, Zheng
    Zhang, Wenhai
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 673 - +
  • [29] Estimation of Fault Location and Fault Resistance for Single Line-to-ground Faults in Multi-ring Distribution Network Using Artificial Neural Network
    Al-Shaher, Meshal
    Saleh, Ahmad S.
    Sabry, Manar M.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (07) : 697 - 713
  • [30] Ways to detect single-line-to-ground faults in electricity transmission lines using the location method
    Minullin R.G.
    Petrushenko Yu.Ya.
    Fardiev I.Sh.
    Lukin E.I.
    Lukina G.V.
    Russian Electrical Engineering, 2008, 79 (12) : 655 - 663