Single-line-to-ground fault location in the compensated distribution network

被引:1
|
作者
Xu, B. [1 ,2 ,3 ,4 ]
Cai, X. [1 ,2 ,3 ,4 ]
Zhu, M.J. [1 ,2 ,3 ,4 ]
Qin, H. [1 ,2 ,3 ,4 ]
Xi, D.M. [1 ,2 ,3 ,4 ]
机构
[1] Wind Power Research Center, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
[2] Jinshan Power Supply Company, SMEPC, Shanghai, China
[3] Shinan Power Supply Company, SMEPC, Shanghai, China
[4] School of Electric Power, Inner Mongolia University of Technology, Hohhot, China
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Electric power distribution - Fast Fourier transforms - Signal generators - Electric grounding - Location
引用
收藏
页码:449 / 458
相关论文
共 50 条
  • [1] New algorithm for location of single-line-to-ground fault on radial distribution network
    Jia, Wenchao
    Xu, Chengbin
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2000, 32 (02): : 118 - 120
  • [2] Active Location Method for Single-Line-to-Ground Fault of Flexible Grounding Distribution Networks
    Lin, Jiahao
    Guo, Moufa
    Zheng, Zeyin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [3] Single-Line-to-Ground Fault Location in Resonant Grounded Systems Based on Fault Distortions
    Chen, Yougen
    Yin, Junbo
    Li, Zhiyong
    Wei, Renyong
    IEEE ACCESS, 2021, 9 (09): : 34325 - 34337
  • [4] New algorithm for the single-line-to-ground fault location in the 10kV or 6kV direct distribution line
    Shu, Hongchun
    Xu, Chengbin
    Xu, Xianmin
    Chen, Xueyun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 1995, 15 (06): : 423 - 428
  • [5] Single terminal fault location to single-line-to-ground fault in T transmission line based on sequenced time session data
    Wang B.
    Lu Y.
    1600, Chinese Society for Electrical Engineering (36): : 2611 - 2618
  • [6] Sequential Data-Based Fault Location for Single-Line-to-Ground Fault in a T-Connection Power Line
    Li, Lisheng
    Yu, Haidong
    Wang, Bin
    Liu, Yang
    Lu, Yuanyuan
    Liu, Wenbin
    ENERGIES, 2024, 17 (12)
  • [7] Location of Single-Line-to-Ground Fault Using 1-D Convolutional Neural Network and Waveform Concatenation in Resonant Grounding Distribution Systems
    Guo, Mou-Fa
    Gao, Jian-Hong
    Shao, Xiang
    Chen, Duan-Yu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [8] Single-line-to-ground Fault Location in Wind Farm Collection Line With Neutral Point Grounding With Resistor
    Wang B.
    Ren X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (06): : 2136 - 2143
  • [9] Impedance fault location algorithm for UHV long transmission lines with single-line-to-ground faults
    State Key Lab. of Control and Simulation of Power Systems and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    不详
    Dianli Xitong Zidonghue, 2008, 14 (25-29): : 25 - 29
  • [10] Design of a Single-Line-to-Ground Fault Detection and Location System using Phasor Measurement Units
    Aljundi, Abdulghani
    Hajjat, Mustafa
    Faza, Ayman
    2021 IEEE JORDAN INTERNATIONAL JOINT CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION TECHNOLOGY (JEEIT), 2021, : 55 - 60