The Performance and Robustness of Power Protection Schemes for Grid-Connected PV Systems Under Varied Smart Inverter Controllers

被引:1
作者
Alasali, Feras [1 ]
El-Naily, Naser [2 ]
Loukil, Hassen [3 ]
Omran, Emad El Deen [4 ]
Holderbaum, William [5 ]
Elhaffar, Abdelsalam [6 ]
Saidi, Abdelaziz Salah [7 ]
机构
[1] Hashemite Univ, Fac Engn, Dept Elect Engn, POB 330127, Zarqa 13133, Jordan
[2] Coll Elect & Elect Technol Benghazi, Benghazi, Libya
[3] King Khalid Univ, Coll Engn, Dept Elect Engn, Abha 61421, Saudi Arabia
[4] Suez Canal Author, Engn Dept, Ismailia, Egypt
[5] Manchester Metropolitan Univ, Sci & Engn, Manchester M1 5GD, England
[6] Sultan Qaboos Univ, Dept Elect Engn, Seeb, Oman
[7] Univ Tunis El Manar, Natl Sch Engineers Tunis, Elect Syst Lab, Tunis, Tunisia
关键词
distribution generation; optimal coordination; overcurrent relays; PV controllers; DISTRIBUTION NETWORKS; RESOURCES; IMPACT; OPTIMIZATION; MICROGRIDS;
D O I
10.1155/2024/6805410
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing use of inverter-based distributed generation requires a comprehensive study of its effects on fault analysis and the effectiveness of protection systems in distribution networks. This study examines the impact of different inverter control modes on multiple types of protective relay schemes. These include different overcurrent relay (OCR) schemes, both standard and nonstandard tripping characteristics, optimal coordination approaches, and different grid operation scenarios. The investigation is conducted through the utilization of grid-connected and islanding operation modes, with fault resistance values of 0 and 5 Omega. The study is carried out on a 14-bus CIGRE network which includes two photovoltaic (PV) farms with a capacity of 10 MVA each. The research provides several significant contributions, including the analysis of fault current contributions, examination of issues in OCR protection, investigation of the influence of fault impedance levels on OCR performance, evaluation of ideal coordination methods, and carrying out a comparative analysis utilizing optimization technique by using the water cycle optimization algorithm (WCA) and the particle swarm optimization algorithm (PSO). In addition, to guarantee the robustness of the suggested protection strategy, this work adopts a hardware-in-the-loop approach. The OMICRON-256 system is utilized to carry out real-time testing on a SIPROTEC 7SJ62 multifunction protection relay, which validates the effectiveness of the proposed method in protecting microgrids under different PV control strategies. The total operating time for the nonstandard tripping scheme was 12.077-12.3003 s for PSO and WCA, respectively, while for the standard tripping scheme, it was 12.1226 and 12.1564 s. Moreover, these findings offer practical insights that can assist operators in effectively designing the power networks with grid-connected PV systems by showing OCR miscoordination and no tripping events in power systems with PVs under inverters controllers.
引用
收藏
页数:29
相关论文
共 62 条
[21]   Impact of Inverter-Based Resources on Negative Sequence Quantities-Based Protection Elements [J].
Haddadi, Aboutaleb ;
Zhao, Mingxuan ;
Kocar, Ilhan ;
Karaagac, Ulas ;
Chan, Ka Wing ;
Farantatos, Evangelos .
IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) :289-298
[22]  
Hester S., 2000, WORKSH P SOL EL POW
[23]   Fault Analysis on Distribution Feeders With High Penetration of PV Systems [J].
Hooshyar, Hossein ;
Baran, Mesut E. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) :2890-2896
[24]  
IEC, IEC TR 60909-4
[25]  
IEEE, 2022, IEEE Std 2800-2022, P1, DOI [DOI 10.1109/IEEESTD.2022.9762253, 10.1109/IEEESTD. 2022.9762253]
[26]  
IEEE, 2001, Standards Association 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (ANSI)
[27]  
IEEE Industry Applications Society, 2018, STD30023 IEEE RECOMM
[28]  
International Electrotechnical Commission (IEC), IEC 60909-0: 2016) 2016 149 Technical report
[29]  
Katiraei F., 2012, P W PROT REL C WASH, P1
[30]  
Keller James., 2010, NREL/TP-550-46698