Temperature field calculation for steam superheater explosive membrane

被引:0
|
作者
Qiao, Xue-Dong [1 ]
Feng, Yu-Heng [1 ]
Hu, Wen-Jun [1 ]
Hou, Zhi-Feng [1 ]
机构
[1] China Institute of Atomic Energy, P.O.275-95, Beijing 102413, China
关键词
Computational fluid dynamics - Explosives - Heat transfer - Argon;
D O I
暂无
中图分类号
学科分类号
摘要
The steam superheater explosive membrane is a kind of important reactor protection equipment against overpressure. In the paper, the temperature field was analyzed using the CFD method. The result reviews that the peak point of temperature is not exceed, and the safety of the equipment is proved.
引用
收藏
页码:155 / 157
相关论文
共 50 条
  • [41] Modeling of transient operation of steam superheater in CFB boiler
    Madejski, Pawel
    Taler, Dawid
    Taler, Jan
    ENERGY, 2019, 182 : 965 - 974
  • [42] Neural Network Based Superheater Steam Temperature Control for a Large-Scale Supercritical Boiler Unit
    Ma, Liangyu
    Lee, Kwang Y.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [43] CALCULATION OF THE TEMPERATURE CONDITIONS OF THE FURNACE WATERWALLS OF STEAM BOILERS
    KALININ, BP
    TOKAR, IY
    THERMAL ENGINEERING, 1981, 28 (05) : 305 - 307
  • [44] Application of the Residue Method in Steam Superheater Fault Detection
    Maican, Camelia Adela
    Radulescu, Virginia Maria
    Pana, Cristina Floriana
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [45] The temperature distribution in the superheater tube
    Tuma, JV
    Kranjc, J
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2001, 66 (04): : 153 - 156
  • [46] Thermal transfer analysis with a Heizmann steam superheater.
    Berner, O
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1905, 49 : 564 - 570
  • [47] Superheater Steam Temperature Control for a 300MW Boiler Unit with Inverse Dynamic Process Models
    Ma, Liangyu
    Lin, Yongjun
    Lee, Kwang Y.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [48] Multi-objective optimization for advanced superheater steam temperature control in a 300 MW power plant
    Sun, Li
    Hua, Qingsong
    Shen, Jiong
    Xue, Yali
    Li, Donghai
    Lee, Kwang Y.
    APPLIED ENERGY, 2017, 208 : 592 - 606
  • [49] HIGH TEMPERATURE CORROSION RESISTANT CHARACTERISTICS OF SUPERHEATER TUBES FOR SUPER-HIGH PRESSURE AND HIGH TEMPERATURE STEAM GENERATOR.
    Ohtomo, Akira
    Kihara, Shigemitsu
    Hamao, Yoshio
    Shigeta, Jun-ichi
    Ando, Sakae
    Aoki, Hiroshi
    IHI Engineering Review (English Edition), 1983, 16 (04): : 310 - 317
  • [50] Temperature Field Calculation for Bridges: Implementation with Spreadsheet Calculation
    Sanio, David
    Mark, Peter
    Ahrens, Mark Alexander
    BETON- UND STAHLBETONBAU, 2017, 112 (02) : 85 - 95