3D printed microplasma optical emission spectrometry coupled with ZIF-8 based dispersive solid-phase extraction for field analysis of waterborne arsenic

被引:0
|
作者
Yang, Jiahui [1 ]
Lin, Yao [3 ]
Wang, Xi [2 ]
Li, Yuanyuan [2 ]
Deng, Yurong [2 ]
Zheng, Chengbin [2 ]
机构
[1] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Chem, Key Lab Green Chem & Technol MOE, Chengdu 610064, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
关键词
waterborne arsenic; Microplasma optical emission spectrometry; 3D printing; Point discharge; Dispersive solid-phase extraction; Field analysis; VAPOR GENERATION; DISCHARGE; NANOPARTICLES; ANTIMONY; REMOVAL; IRON;
D O I
10.1016/j.aca.2024.343270
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Arsenic contamination of drinking water has become a public health challenge over the world, particularly in Bangladesh, India, and China. Compared to the most used field test kits of waterborne arsenic, miniature microplasma atomic spectrometry retains advantages of accuracy, elemental specificity, and less matrix interference. Despite increased interest in arsenic detection by using miniature microplasma spectrometry, the improvements of its analytical performance, manufacturing cost and consistency still remain significant challenges. Results Herein, a miniature, battery-operated, and integrated hydride generation point discharge optical emission spectrometer (HG-mu PD-OES, 116 mm length x 92 mm width x 104 mm height) was printed with a simple 3D printer and used for the highly sensitive and element-specific determination of arsenic by coupling to a dispersive solid-phase extraction (d-SPE) using zeolitic imidazolate framework-8 as adsorbent. The d-SPE simplifies sample treatment, significantly alleviates the interference arising from transition metal ions and improves sensitivity. A LOD of 0.07 mu g L-1 for arsenic was obtained with relative standard deviations (RSDs, n = 11) better than 3.8 %. Significance The 3D printing technique significantly improves the manufacturing cost and fabricating consistency of HG-mu PD-OES. LOD were remarkably improved 27-fold compared to those obtained by conventional HG-mu PD-OES, providing a promising method for the reliable, sensitive, and convenient field analysis of waterborne arsenic even its concentration as low as 0.2 mu g L-1. The practicability and accuracy of the proposed method have been successfully verified via the field analysis of waterborne arsenic in a Certified Reference Material (GBW(E)080390) and a series of river and lake water samples.
引用
收藏
页数:9
相关论文
共 37 条
  • [21] C8-modified magnetic graphene oxide based solid-phase extraction coupled with dispersive liquid-liquid microextraction for detection of trace phthalate acid esters in water samples
    Wang, Rui
    Ma, Xiaoguo
    Zhang, Xiaojun
    Li, Xin
    Li, Danping
    Dang, Yongfeng
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 170 : 789 - 795
  • [22] Determination of five alternaria toxins in peppermint by dispersive solid-phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry based on MOF-808-TFA
    Liu, Minhai
    Zhang, Yan
    Cheng, Rui
    Tan, Ting
    Guo, Lan
    Liu, Fan
    Wan, Yiqun
    FOOD CHEMISTRY, 2025, 471
  • [23] A new carbon-based magnetic material for the dispersive solid-phase extraction of UV filters from water samples before liquid chromatography-tandem mass spectrometry analysis
    Piovesana, Susy
    Capriotti, Anna Laura
    Cavaliere, Chiara
    La Barbera, Giorgia
    Samperi, Roberto
    Chiozzi, Riccardo Zenezini
    Lagana, Aldo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (17) : 4181 - 4194
  • [24] Size-controllable synthesis of large-size spherical 3D covalent organic frameworks as efficient on-line solid-phase extraction sorbents coupled to HPLC
    Chen, Ying
    He, Qiong
    Liu, Yuyang
    Wang, Qiang
    He, Chiyang
    Liu, Shaorong
    ANALYTICA CHIMICA ACTA, 2024, 1287
  • [25] 3-Monochloropropane-1,2-diol Monoesters Food Contaminant Analysis in Palm Oil-Based Food Samples Using C18-Dispersive Solid-Phase Extraction Coupled with GC-FID
    Nur Hasanah Mohd Jumali
    Shangeetha Ganesan
    Noorfatimah Yahaya
    Mazidatulakmam Miskam
    Food Analytical Methods, 2021, 14 : 2101 - 2110
  • [26] Analysis of Imidazole Propionic Acid in Serum of Patients with Type 2 Diabetes Based on NiO@SiO2 Solid-phase Extraction Coupled with Liquid Chromatography-Mass Spectrometry
    Wang, Tianqi
    Yu, Qiongwei
    Feng, Yuqi
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2020, 41 (02): : 262 - 267
  • [27] Magnetic solid-phase extraction based on magnetic multiwalled carbon nanotubes for the simultaneous enantiomeric analysis of five β-blockers in the environmental samples by chiral liquid chromatography coupled with tandem mass spectrometry
    Wang, Zhaokun
    Zhang, Xue
    Jiang, Shenmeng
    Guo, Xingjie
    TALANTA, 2018, 180 : 98 - 107
  • [28] 3-Monochloropropane-1,2-diol Monoesters Food Contaminant Analysis in Palm Oil-Based Food Samples Using C18-Dispersive Solid-Phase Extraction Coupled with GC-FID
    Jumali, Nur Hasanah Mohd
    Ganesan, Shangeetha
    Yahaya, Noorfatimah
    Miskam, Mazidatulakmam
    FOOD ANALYTICAL METHODS, 2021, 14 (10) : 2101 - 2110
  • [29] 3D flower-liked Fe3O4/C for highly sensitive magnetic dispersive solid-phase extraction of four trace non-steroidal anti-inflammatory drugs
    Xu, Xu
    Feng, Xue
    Liu, Zhen
    Xue, Shan
    Zhang, Lei
    MICROCHIMICA ACTA, 2021, 188 (02)
  • [30] Simultaneous enantiomeric analysis of six chiral pesticides in functional foods using magnetic solid-phase extraction based on carbon nanospheres as adsorbent and chiral liquid chromatography coupled with tandem mass spectrometry
    Zhao, Pengfei
    Li, Shuang
    Chen, Xiaoming
    Guo, Xingjie
    Zhao, Longshan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 175