Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections

被引:0
作者
Dawood, Kamran [1 ]
Tursun, Semih [1 ]
Komurgoz, Guven [2 ]
机构
[1] Astor Enerji, Dept Res & Dev, TR-06909 Ankara, Turkiye
[2] Istanbul Tech Univ, Elect Engn Dept, TR-34485 Istanbul, Turkiye
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Cross-section; dry-type transformer; finite element analysis; leakage impedance; INDUCTANCE; REACTANCE;
D O I
10.1109/ACCESS.2024.3487300
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the power transformers. This paper focuses on the numerical estimation for the calculation of leakage impedance with three sections in the primary winding (high-voltage winding) and a single section in the secondary winding (low-voltage winding). This paper aims to comprehensively examine the variations that arise from the different cross-sectional areas of the various sections of the high-voltage winding, as well as how these variations affect the transformer's overall leakage impedance. This study focuses on examining the effect of different cross-section areas of the high-voltage winding on leakage impedance. Finite element analysis is used to measure and evaluate the leakage impedance of the transformer under different configurations. This study examines the impact of cross-sectional area variations on the transformer's leakage impedance, highlighting the crucial roles of impedance and inductance.
引用
收藏
页码:170379 / 170386
页数:8
相关论文
共 24 条
  • [1] [Anonymous], 2004, Transformer engineering: design and practice, DOI DOI 10.1201/9780367800598
  • [2] Loss Minimization-Based Sensorless Control of High-Speed Induction Motor Considering Core Loss
    Ayana, Tadele
    Kolodziejek, Piotr
    Morawiec, Marcin
    Wogi, Lelisa
    [J]. IEEE ACCESS, 2024, 12 : 116341 - 116353
  • [3] Bakar M. A., 2016, P IEEE 16 INT C ENV, P1, DOI [10.1109/EEEIC.2016.7555605, DOI 10.1109/EEEIC.2016.7555605]
  • [4] Analytic formulation for the calculation of leakage reactance in wound-core transformers
    Castaneda Hernandez, Russby Liliana
    Diaz Florez, Guillermo Andres
    Perez Gelves, Jhon Jairo
    Esteban Mombello, Enrique
    [J]. INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2021, 65 (02) : 197 - 213
  • [5] Dawood K., 2017, P 18 INT S EL FIELDS, P1, DOI [10.1109/ISEF.2017.8090696, DOI 10.1109/ISEF.2017.8090696]
  • [6] Optimized gap positions for improved leakage impedance in dry-type transformer design
    Dawood, Kamran
    Tursun, Semih
    [J]. RESULTS IN ENGINEERING, 2024, 23
  • [7] Influence of Core's window height on leakage reactance of power transformers
    Dawood, Kamran
    Tursun, Semih
    [J]. RESULTS IN ENGINEERING, 2023, 20
  • [8] Optimization and analysis of tapping position on leakage reactance of a two winding transformer
    Dawood, Kamran
    Sonmez, Olus
    Komurgoz, Guven
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2023, 69 : 363 - 369
  • [9] Optimization and Analysis of Leakage Reactance for a Converter Transformer of the Electric Transport System
    Dawood, Kamran
    Koemurgoz, Guven
    Isik, Fatih
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2023, 19 (01) : 351 - 360
  • [10] Analysis and optimization of leakage impedance in a transformer with additional winding: A numerical and experimental study
    Dawood, Kamran
    Isik, Fatih
    Komurgoz, Guven
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (12) : 11291 - 11300