Experimental and analytical investigation of bracket moment connection for precast concrete beam-to-composite column joints

被引:1
作者
Eom, Tae-Sung [1 ]
Lee, Seung-Jae [1 ]
Jo, Kwang-Won [2 ]
Kim, Min-Jae [2 ]
Lee, Seung Hwan [3 ]
Hwang, Hyeon-Jong [4 ]
机构
[1] Dankook Univ, Sch Architecture, 152 Jukjeon Ro, Yongin 16890, Gyeonggi Do, South Korea
[2] SENVEX Co Ltd, 6 Beodeunaru Ro 19 Gil, Seoul 150040, South Korea
[3] SEN Coretech Inc, 6 Beodeunaru Ro 19 Gil, Seoul 150040, South Korea
[4] Konkuk Univ, Sch Architecture, Seoul 05029, South Korea
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 96卷
基金
新加坡国家研究基金会;
关键词
Precast concrete; Composite columns; Bracket connection; Moment connection; Beam-column joint; Cyclic load; Seismic performance;
D O I
10.1016/j.jobe.2024.110593
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In large industrial buildings, precast prestressed concrete beams and composite columns are appealing to achieve longer span and higher story height, with temporary supporting and scaffolding minimized. To facilitate field erection of moment connection between precast beams and composite columns, a bracket connection transferring beam loads to the column by connecting the beam to a composite bracket attached to the column has been developed. Since precast beams are lap-spliced and integrated with the bracket by concrete engagement at the interfaces, the connection performance depends on beam lap length and load transfer details (i.e., concrete shear keys). In this study, the seismic performance of precast prestressed concrete beam-to-composite column joints with the bracket connection was experimentally and analytically investigated. Cyclic loading tests were conducted on four full-scale specimens with different beam lap lengths and load transfer details. For the specimens with a longer beam lap length, the bracket connection successfully transferred the beam flexural strength to the column with the connection barely damaged. The governing failure mode was beam flexural yield occurring at the bracket end. However, for the specimen with a shorter beam lap length, relative slips at the interfaces of the beam and bracket occurred and thus the strength was governed by the bracket connection. Excellent ductility satisfying the acceptance limit of special moment frame in AISC 341 was achieved in all specimens. The load transfer at the bracket connection through concrete shear keys and other details were further investigated through finite element analysis. Design models to predict the connection strength were proposed and the validity of the models was verified through comparisons with the tests and analyses.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] A novel precast concrete beam-to-column connection with replaceable energy-dissipation connector: Experimental investigation and theoretical analysis
    Tong, Chao
    Wu, Jing
    Li, Chunyu
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (12) : 4911 - 4943
  • [32] Experimental investigation of a self-centering precast concrete beam-to-column connection with top and bottom friction energy dissipaters
    Huang, Linjie
    Zhou, Zhen
    Peng, Zhen
    Ma, Junfeng
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (04)
  • [33] Experimental Analysis of the Behavior of Composite Column-Reinforced Concrete Beam Joints
    Tunc, Gokhan
    Dakhil, Abdulrrahman
    Mertol, Halit Cenan
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (11) : 10785 - 10801
  • [34] Experimental Analysis of the Behavior of Composite Column-Reinforced Concrete Beam Joints
    Gokhan Tunc
    Abdulrrahman Dakhil
    Halit Cenan Mertol
    Arabian Journal for Science and Engineering, 2021, 46 : 10785 - 10801
  • [35] Experimental study on lateral behavior of precast wide beam-column joints
    Kim, Jae Hyun
    Jang, Beom Soo
    Choi, Seung-Ho
    Lee, Yoon Jung
    Jeong, Ho Seong
    Kim, Kang Su
    EARTHQUAKES AND STRUCTURES, 2021, 21 (06) : 653 - 667
  • [36] Research on rotation capacity of the new precast concrete assemble beam-column joints
    Han, Chun
    Li, Qingning
    Wang, Xin
    Jiang, Weishan
    Li, Wei
    STEEL AND COMPOSITE STRUCTURES, 2016, 22 (03) : 613 - 625
  • [37] Modeling of Precast Reinforced Concrete Beam-column Joints Under Cyclic Loading
    Tarabia, Ahmed M.
    Etman, Emad E.
    Allam, Said M.
    Aboelhassan, Mohamed G.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (14) : 7626 - 7655
  • [38] THEORETICAL INVESTIGATION ON THE MOMENT CONTINUITY OF PRECAST CONCRETE BEAM-COLUMN CONNECTIONS UNDER GRAVITY LOADS
    Hasan, Sarakot
    Ferreira, Marcelo de A.
    Elliott, Kim S.
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 987 - 990
  • [39] Experimental investigation and analytical modeling of steel beam-to-CFDST column connection
    Fan, Junchao
    Zhao, Junhai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 190
  • [40] Experimental investigation on hysteretic performance and deformation patterns of single-side yielding precast concrete beam-column connection with energy dissipation bars
    Zhu, Yunqing
    Wu, Jing
    Xie, Luqi
    ENGINEERING STRUCTURES, 2021, 245