A capacitor-current real-time feedback active damping method for improving robustness of the LCL-type grid-connected inverter

被引:0
|
作者
机构
[1] Pan, Donghua
[2] Ruan, Xinbo
[3] Wang, Xuehua
[4] Bao, Chenlei
[5] Li, Weiwei
来源
Pan, D. (pan_dh@hust.edu.cn) | 1600年 / Chinese Society for Electrical Engineering卷 / 33期
关键词
23;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Complete Time-Delay Compensation Method for LCL-Type Grid-Connected Inverter with Capacitor-Current Active Damping
    Li, Shaojie
    Lin, Hua
    Wang, Xingwei
    Hua, Ting
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 3484 - 3489
  • [2] Damping region extension for digitally controlled LCL-type grid-connected inverter with capacitor-current feedback
    Liu, Jinhong
    Zhou, Lin
    Molinas, Marta
    IET POWER ELECTRONICS, 2018, 11 (12) : 1974 - 1982
  • [3] Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Bao, Chenlei
    Li, Weiwei
    Wang, Xuehua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) : 3414 - 3427
  • [4] Robust Capacitor-Current-Feedback Active Damping for the LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    Bao, Chenlei
    Li, Weiwei
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 728 - 735
  • [5] Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation
    He, Yuying
    Wang, Xuehua
    Ruan, Xinbo
    Pan, Donghua
    Xu, Xingping
    Liu, Fuxin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (12) : 12423 - 12436
  • [6] High Robustness Grid Current Feedback Active Damping Strategy for LCL-type Grid-connected Inverter in Weak Grid
    Dong G.
    Xu Z.
    Sun P.
    Li Q.
    Chen Y.
    Dianwang Jishu/Power System Technology, 2024, 48 (04): : 1672 - 1680
  • [7] Novel Capacitor Current Feedback Active Damping Strategy for Enhancing Robustness of LCL-type Grid-connected Inverters
    Cao Z.
    Xiao X.
    Ma J.
    Luo D.
    Yang X.
    Yu H.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (11): : 3781 - 3789
  • [8] A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness
    Li, Shaojie
    Lin, Hua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6462 - 6474
  • [9] Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method
    Li, Xiaoqiang
    Wu, Xiaojie
    Geng, Yiwen
    Yuan, Xibo
    Xia, Chenyang
    Zhang, Xue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5247 - 5259
  • [10] An Active Capacitor Converter for Improving Robustness of the LCL-Type Grid-Connected Inverter against Grid Impedance Variation
    Zhou, Qingfeng
    Wang, Xuehua
    Ruan, Xinbo
    Teng, Yu
    Liu, Fuxin
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 3608 - 3613