Low-Cost Device for Measuring Wastewater Flow Rate in Open Channels

被引:2
作者
Wotzka, Daria [1 ]
Zmarzly, Dariusz [1 ]
机构
[1] Opole Univ Technol, Fac Elect Engn Automat Control & Informat, PL-45758 Opole, Poland
关键词
low-cost device; flow rate determination; ultrasound velocity measurement; wastewater level measurement; open channel; cross-correlation; VELOCITY PROFILE MEASUREMENT; ULTRASONIC FLOWMETERS; DOPPLER; ACCURACY; ALGORITHM; MODEL;
D O I
10.3390/s24206607
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research paper describes the development of a low-cost device for measuring wastewater flow rates in open channels, a significant advancement enabled by the evolution of microcomputers and processing techniques. A laboratory setup was constructed to validate the device's accuracy against a standard flow measurement method, optimizing key parameters to achieve a linear relationship between detected and set flow rates, while considering hardware limitations and energy efficiency. The central focus of the research was developing a method to measure the velocity of contaminated fluid using ultrasonic signals, employing the cross-correlation method for signal delay analysis in a stochastic environment. This was complemented by a procedure to measure fluid levels, also based on ultrasonic signals. The device's reliability was assessed through repeatability and uncertainty measurements, confirming its accuracy with an extended uncertainty not exceeding an average of 3.47% for flows above 40 L/min. The device has potential to provide valuable data on the operational dynamics of sanitary networks, crucial for developing and calibrating simulation models.
引用
收藏
页数:21
相关论文
共 57 条
[1]   Ultrasonic device for real-time sewage velocity and suspended particles concentration measurements [J].
Abda, F. ;
Azbaid, A. ;
Ensminger, D. ;
Fischer, S. ;
Francois, P. ;
Schmitt, P. ;
Pallares, A. .
WATER SCIENCE AND TECHNOLOGY, 2009, 60 (01) :117-125
[2]   Algorithm with improved accuracy for real-time measurement of flow rate in open channel systems [J].
Agu, Cornelius E. ;
Hjulstad, Asmund ;
Elseth, Geir ;
Lie, Bernt .
FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 57 :20-27
[3]   Monte Carlo uncertainty assessment of ultrasonic beam parameters from immersion transducers used to non-destructive testing [J].
Alvarenga, A. V. ;
Silva, C. E. R. ;
Costa-Felix, R. P. B. .
ULTRASONICS, 2016, 69 :144-151
[4]   Comparison of ADV and PIV measurements in open channel flows [J].
Bai Ruonan ;
Cao Liekai ;
Wang Xingkui ;
Li Danxun .
12TH INTERNATIONAL CONFERENCE ON HYDROINFORMATICS (HIC 2016) - SMART WATER FOR THE FUTURE, 2016, 154 :995-1001
[5]  
Balmforth NJ, 2001, LECT NOTES PHYS, V582, P34
[6]  
Bankston J.David., 1995, OPEN CHANNEL FLOW AQ
[7]  
Basu S., 2019, Plant Flow Measurement and Control Handbook, P395
[8]  
Basu S., 2019, Plant Flow Measurement and Control Handbook. Fluid, Solid, P257
[9]   A flowmeter for unsteady liquid flow measurements [J].
Beaulieu, A. ;
Foucault, E. ;
Braud, P. ;
Micheau, P. ;
Szeger, P. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2011, 22 (02) :131-137
[10]  
Berg C., 2015, IFAC - Papers Online, V48, P171, DOI 10.1016/j.ifacol.2015.08.027