Evaluation of small animal imaging under different scan conditions

被引:0
|
作者
Jia, Pengxiang [1 ]
Wang, Haoyu [1 ,3 ]
Yan, Bin [2 ]
Li, Lei [2 ]
Chen, Jian [2 ]
Zhang, Feng [2 ]
Bao, Shanglian [1 ,4 ]
机构
[1] Beijing City Key Lab of Medical Physics and Engineering, Peking University, Beijing 100871, China
[2] China National Digital Switching System Engineering and Technological Research Center, Zhengzhou 450002, China
[3] Handling Equipment Mechanical Department, Academy of Military Transportation, Tianjin 300161, China
[4] Beijing Healthware Science and Technology Inc., Beijing 100084, China
关键词
MATLAB - Intelligent systems - Monte Carlo methods - Computerized tomography - Animals - X ray detectors;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging.
引用
收藏
页码:27 / 33
相关论文
共 50 条
  • [1] Imaging evaluation of the small animal mediastinum
    Diana, A.
    Pivetta, M.
    Cipone, M.
    VETERINARY RESEARCH COMMUNICATIONS, 2006, 30 : 145 - 151
  • [2] Imaging Evaluation of the Small Animal Mediastinum
    A. Diana
    M. Pivetta
    M. Cipone
    Veterinary Research Communications, 2006, 30 : 145 - 151
  • [3] Evaluation of different rectangular scan strategies for STEM imaging
    Velazco, A.
    Nord, M.
    Beche, A.
    Verbeeck, J.
    ULTRAMICROSCOPY, 2020, 215
  • [4] Evaluation of scan strategies for small animal in vivo micro-CT
    Dudak, J.
    Ekendahl, D.
    Judas, L.
    Mrzilkova, J.
    Rubovic, P.
    Zach, P.
    Zemlicka, J.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [5] An Objective Evaluation Method for Image Sharpness Under Different Illumination Imaging Conditions
    He, Huan
    Jiang, Benchi
    Shi, Chenyang
    Lu, Yuelin
    Lin, Yandan
    PHOTONICS, 2024, 11 (11)
  • [6] Monitoring of small lymphatics function under different impact on animal model by integrated optical imaging
    Galanzha, EI
    Tuchin, VV
    Chowdhury, P
    Zharov, VP
    SARATOV FALL MEETING 2003: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE V, 2004, 5474 : 204 - 214
  • [7] Development and evaluation of a MicroCT system for small animal imaging
    Song, X
    Frey, EC
    Tsui, BMW
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1600 - 1604
  • [8] Quality Evaluation of Mackerel Fillets Stored under Different Conditions by Hyperspectral Imaging Analysis
    Ismail, Azfar
    Ryu, Jiwon
    Yim, Dong-Gyun
    Kim, Ghiseok
    Kim, Sung-Su
    Lee, Hag Ju
    Jo, Cheorun
    FOOD SCIENCE OF ANIMAL RESOURCES, 2023, 43 (05) : 840 - 858
  • [9] Study of different pinhole configurations for small animal tumor imaging
    Bal, G
    Zeng, GL
    Lewitt, RM
    Cao, Z
    Acton, PD
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3133 - 3137
  • [10] EVALUATION OF ANIMAL PRODUCTION UNDER DIFFERENT SYSTEMS OF GRAZING
    KENNEDY, WK
    REID, JT
    ANDERSON, MJ
    JOURNAL OF DAIRY SCIENCE, 1959, 42 (04) : 679 - 685