摘要
In order to address the problem of coexistence of overvoltage, overcurrent, and voltage drop at the wind farm grid connection point caused by single-phase grounding faults on the transformer side of the offshore wind power system, we put forward a stress control method for symmetrical bipolar offshore wind power system faults based on system parameter optimization. Firstly, we constructed a mathematical model for the converter valve and a control model for wind turbines, and revealed the overvoltage, overcurrent and the voltage drop characteristics of the converter valve after faults and their impact on the wind farm grid connection points. Secondly, on the basis of the impact mechanism of system key parameters on post fault voltage and current, we proposed a fault stress control scheme based on system parameter optimization. By optimizing the configuration of system key parameters, the control of overvoltage, overcurrent, and low voltage can be realized, significantly extending the safe operation time after system faults and improving the voltage at the wind farm grid connection point. Finally, we verified the effectiveness of the proposed method in regulating system fault stress through simulation analysis of a flexible DC system for symmetrical bipolar offshore wind power. This method can provide support for the optimization design of offshore wind power. © 2024 Science Press. All rights reserved.
引用
收藏
页码:4640 / 4654
相关论文
共 13 条
  • [11] Single-Phase to Ground Fault Current Distribution in Transmission System Based on the Improved Double-side Elimination Method
    Qi, Zheng
    Rao, Zhi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 11 (04) : 417 - 424
  • [12] Control strategies of offshore wind power low frequency transmission system under asymmetric fault of low-frequency side
    Gao X.
    Zhang C.
    Song G.
    Jiang J.
    Lü Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (10): : 160 - 166
  • [13] Primary Side Control Method of Wireless Power Transmission System Based on Load Resistance Identification
    Qian, Qiang
    Zhao, Zijian
    Liang, Wenxi
    Cai, Zicheng
    PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 1, ICWPT 2023, 2024, 1158 : 606 - 613