Application of six-sequence fault components in fault location for joint parallel transmission line

被引:10
作者
机构
[1] Dept. of Elec. Eng., Shanghai Jiaotong Univ.
来源
Fan, C. (chunjuc@online.sh.cn) | 2005年 / Tsinghua University Press卷 / 10期
关键词
Fault location; Joint parallel line; Six-sequence components; Two-terminal;
D O I
10.1016/S1007-0214(05)70062-6
中图分类号
学科分类号
摘要
A new fault location method based on six-sequence fault components was developed for parallel lines based on the fault analysis of a joint parallel transmission line. In the six-sequence fault network, the ratio of the root-mean square value of the fault current from two terminals is the function of the line impedance, the system impedance, and the fault distance away from the buses. A fault location equation is given to relate these factors. For extremely long transmission lines, the distributed capacitance is divided by the fault point and allocated to the two terminals of the transmission line in a lumped parameter to eliminate the influence of the distributed capacitance on the location accuracy. There is no limit on fault type and synchronization of the sampling data. Simulation results show that the location accuracy is high with an average error about 2%, and it is not influenced by factors such as the load current, the operating mode of the power system, or the fault resistance.
引用
收藏
页码:247 / 253
页数:6
相关论文
共 13 条
[1]  
Takagi T., Yamakoshi Y., Baba Y., Uemura K., Sakaguchi T., A new algorithm of an accurate fault location for EHV/UHV transmission lines, IEEE Transactions on Power Apparatus and Systems, 100, 3, pp. 1316-1323, (1981)
[2]  
Takagi T., Yamakoshi Y., Yamaura M., Kondou R., Matsushima T., Development of a new type fault locator using the one-terminal voltage and current data, IEEE Transactions on Power Apparatus and Systems, 101, 8, pp. 2892-2898, (1982)
[3]  
Zhang Q., Zhang Y., Song W., Yu Y., Wang Z., Fault location of two-parallel transmission line for non-earth fault using one-terminal data, Power Engineering Society 1999 Winter Meeting, IEEE, 2, pp. 967-967, (1999)
[4]  
Li Y., Li Z., Lu Z., Niu C., Chen X., Using new algorithm of single terminal for the locating fault point on double circuit lines, Power System Engineering, 16, 5, pp. 301-304, (2000)
[5]  
Suonan J., Wu Y., Song G., Liu H., Wang S., Accurate fault location scheme for parallel transmission line based on distributed parameter, Proceedings of China University Society-Electrical Power System Automation (CUS-EPSA), pp. 929-935, (2002)
[6]  
Nagasawa T., Abe M., Otsuzuki N., Emura T., Jikihara Y., Takeuchi M., Development of a new fault location algorithm for multi-terminal two parallel transmission lines, IEEE Transactions on Power Delivery, 7, 3, pp. 1516-1532, (1992)
[7]  
Novosel D., Hart D.G., Udren E., Garitty J., Unsynchronized two-terminal fault location estimation, IEEE Transactions on Power Delivery, 11, 1, pp. 130-138, (1996)
[8]  
Funabashi T., Otoguro H., Mizuma Y., Dube L., Ametani A., Digital fault location for parallel double-circuit multi-terminal transmission lines, IEEE Transactions on Power Delivery, 15, 4, pp. 531-537, (2000)
[9]  
Jiang J.-A., Yang J.-Z., Lin Y.-H., Liu C.-W., Ma J.-C., An adaptive PMU based fault detection/location technique for transmission lines: Part I, Theory and algorithms, IEEE Transactions on Power Delivery, 15, 2, pp. 486-493, (2000)
[10]  
Chen C.-S., Liu C.-W., Jiang J.-A., A new adaptive PMU based protection scheme for trans-posed/untransposed parallel transmission lines, IEEE Transactions on Power Delivery, 17, 4, pp. 395-404, (2002)