Uniaxial tensile testing device for measuring mechanical properties of biological tissue with stress-relaxation test under a confocal microscope

被引:0
作者
Vondrášek D. [1 ,2 ]
Hadraba D. [1 ,2 ]
Matějka R. [2 ]
Lopot F. [1 ]
Svoboda M. [3 ]
Jelen K. [1 ]
机构
[1] Faculty of Physical Education and Sport, Charles University, Prague
[2] Institute of Physiology, Czech Academy, Prague
[3] Faculty of Mechanical Engineering, Jan Evangelista Purkyne University in ústí nad Labem, Pasteurova 1, ústí nad Labem
来源
Manufacturing Technology | 2018年 / 18卷 / 05期
关键词
Biomechanical models; Fibroproliferative diseases; Maxwell-Wiechert's model; Mechanical properties of biological tissues; Porcine pericardium; Stress-relaxation test; Talipes equinovarus congenitus; Uniaxial tensile test;
D O I
10.21062/ujep/180.2018/a/1213-2489/MT/18/5/866
中图分类号
学科分类号
摘要
Biological soft tissue is a non-linear and viscoelastic material and its mechanical properties can greatly affect quality of life. Many external mechanical factors can alter the tissue, for example the tissue of talipes equinovarus congenitus, also known as clubfoot, which is the most frequent congenital deformity affecting lower extremities with pathological changes of connective tissue. In clubfoot, the presence of disc-like mass of fibrous tissue, resembling intervertebral disc tissue, is described to be between the medial malleolus and the medial side of the navicular bone. The clubfoot tissue is often referred to be stiffer or rigid by clinicians, or it is referred to as contracted and less contracted tissue, however relevant evidence about mechanical properties is missing. Therefore, the description "disc-like" is informing only about relative mechanical properties of clubfoot tissue. We aim to prepare methodical approach to quantify mechanical properties of biological tissue with uniaxial tensile stress-relaxation test, in order to help clinicians and scientist to identify precisely the mechanical properties of normal and pathological tissue and their structural behaviour during mechanical testing. In this study, we test and tune the uniaxial tensile stress-relaxation test on biological tissue with high content of connective tissue such as collagen. The model tissue is porcine pericardium. The tissue has clear collagen fibres aligning parallel to the force applied. Modulus of elasticity measured here is comparable to other studies. © 2018. Published by Manufacturing Technology.
引用
收藏
页码:866 / 872
页数:6
相关论文
共 37 条
  • [1] Haslach H.W., Nonlinear Viscoelastic, Thermodynamically Consistent, Models for Biological Soft Tissue, , Biomech. Model. Mechanobiol, 3, 3, pp. 172-189, (2005)
  • [2] Badylak S., Freytes D., Gilbert T., Extracellular Matrix as a Biological Scaffold Material: Structure and Function, , Acta Biomater, 5, 1, pp. 1-13, (2009)
  • [3] Valasek P., Tensile Strength of Sisal/ Epoxy Composites Prepared by Vacuum Infusion, , Manuf Technol, 17, pp. 869-874, (2017)
  • [4] Duenwald S.E., Vanderby R., Lakes R.S., Viscoelastic Relaxation and Recovery of Tendon, , Ann. Biomed. Eng, 37, 6, pp. 1131-1140, (2009)
  • [5] L'Heureux N., Paquet S., Labbe R., Germain L., Auger F.A., A Completely Biological Tissue-Engineered Human Blood Vessel, , FASEB J, 12, 1, pp. 47-56, (1998)
  • [6] Kjaer M., Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading, , Physiol. Rev, 84, 2, pp. 649-698, (2004)
  • [7] Miller K., Chinzei K., Mechanical Properties of Brain Tissue in Tension, , J. Biomech, 35, 4, pp. 483-490, (2002)
  • [8] Thomasy S.M., Krishna Raghunathan V., Winkler M., Reilly C.M., Sadeli A.R., Russell P., Jester J.V., Murphy C.J., Elastic Modulus and Collagen Organization of the Rabbit Cornea: Epithelium to Endothelium, , Acta Biomater, 10, 2, pp. 785-791, (2014)
  • [9] Svoboda M., Soukup J., Jelen K., Kubovy P., Effect of Impacts on Human Head, , Manuf Technol, 15, pp. 226-231, (2015)
  • [10] Bittner V., Tucek R., Panska S., Svoboda M., Jelen K., Using the Fourier Transform in the Analysis of Vibration Load Tests of Heterogeneous Mechanical Systems, , Manuf Technol, 17, pp. 836-841, (2017)