Key Technology of Relay Protection System-level Testing Considering Comprehensive Optimization of Substation Secondary System

被引:0
作者
Meng J. [1 ]
Li Z. [1 ]
Zhan R. [1 ]
Mou L. [2 ]
Zhou Z. [1 ]
Xu K. [3 ]
Yu Y. [1 ]
Ren Y. [2 ]
机构
[1] State Key Laboratory of Power Grid Safety, China Electric Power Research Institute, Haidian District, Beijing
[2] State Grid of China Technology College, Shandong Province, Jinan
[3] State Grid Corporation of China, Xicheng District, Beijing
来源
Dianwang Jishu/Power System Technology | 2023年 / 47卷 / 09期
关键词
optimization; relay protection; secondary system; substation; system-level test;
D O I
10.13335/j.1000-3673.pst.2022.2155
中图分类号
学科分类号
摘要
The optimization of the substation secondary system has completed the overall improvement of the secondary system from the technical architecture to the functional design. The reliable operation of the relay protection, the core business of the secondary system, is the key basis for the safe and stable operation of the power grid. In order to fully assess and verify the reliability of the new generation relay protection system, this paper first analyzes the innovation points of the relay protection technology and the resulting operation risks from the aspects of autonomous control, function optimization, operation monitoring and safety enhancement on the premise of the comprehensive optimization of substation secondary system. Moreover, on the basis of sorting out the interactive data flow of the relay protection functions, the key technologies of the relay protection system-level testing are discussed. Test methods for the relay protection in terms of the operation performance under the complex working conditions, the configuration control, the functional interaction and the virtual loop reliability are proposed. In the end, a relay protection system-level test platform is established, accompolishing the comprehensive assessment and verification of the relay protection action performance and function, which is of great significance for eliminating the equipment defects, reducing the peration risks and accelerating the practical process of the optimization scheme. © 2023 Power System Technology Press. All rights reserved.
引用
收藏
页码:3791 / 3798
页数:7
相关论文
共 18 条
[1]  
(2005)
[2]  
(2018)
[3]  
(2010)
[4]  
QIU Yutao, HU Xueping, LING Guang, Research on state grid’ s technical specification system of relay protection in smart substation[J], Power System Protection and Control, 45, 20, pp. 7-13, (2017)
[5]  
(2010)
[6]  
SONG Xunkun, Liu HAN, JU Huangpei, A review on development practice of smart grid technology in China[J], Electric Power Construction, 37, 7, pp. 1-11, (2016)
[7]  
LI Mingjie, LIU Yu, SHU Zhihuai, Research and judgement on technical development trend of substation secondary system in China[C], CIGRE 2022 session
[8]  
YAO Zhiqiang, CHANG Naichao, DOU Renhui, Optimization of data stream between substation and dispatching adapting to centralized control[J], Power System Technology, 46, 10, pp. 4113-4121, (2022)
[9]  
HE Chun, ZHANG Ran, Experimental summary on IEC 61850 international interoperability test[J], Automation of Electric Power Systems, 36, 2, pp. 6-10, (2012)
[10]  
ZHOU Chunxia, ZHAN Rongrong, JIANG Jianning, Dynamic simulation test for 500 kV digital substation[J], Power System Technology, 34, 6, pp. 193-197, (2010)