The frequency-controlled asynchronous drive with control relative to the modulus of the motor's stator current was discussed. Analysis of the electromagnetic processes in the electric drive under control was difficult. The AM axle speed was regulated by specifying the signal, which essentially determined the mean modulus of the inverter output voltage. The inverter switching frequency was established automatically as a function of the load at the motor axle and the modulus of the stator current.