Transient AC Overvoltage Suppression Orientated Reactive Power Control of the Wind Turbine in the LCC-HVDC Sending Grid

被引:3
|
作者
Pang, Bo [1 ]
Jin, Xiao [2 ]
Zhang, Quanwang [1 ]
Tang, Yi [1 ]
Liao, Kai [1 ]
Yang, Jianwei [1 ]
He, Zhengyou [1 ]
机构
[1] Southwest Jiaotong Univ, Coll Elect Engn, Chengdu 610031, Peoples R China
[2] State Grid Zhejiang Elect Power Co, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Commutation failure; LCC-HVDC; Transient overvoltage; Wind power; STRATEGY; DESIGN;
D O I
10.30941/CESTEMS.2024.00020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-voltage direct current (HVDC) transmission is a crucial way to solve the reverse distribution of clean energy and loads. The line commutated converter-based HVDC (LCC-HVDC) has become a vital structure for HVDC due to its high technological maturity and economic advantages. During the DC fault of LCC-HVDC, such as commutation failure, the reactive power regulation of the AC grid always lags the DC control process, causing overvoltage in the AC sending grid, which brings off-grid risk to the wind power generation based on power electronic devices. Nevertheless, considering that wind turbine generators have fast and flexible reactive power control capability, optimizing the reactive power control of wind turbines to participate in the transient overvoltage suppression of the sending grid not only improves the operational safety at the equipment level but also enhances the voltage stability of the system. This paper firstly analyses the impact of wind turbine's reactive power on AC transient overvoltage. Then, it proposes an improved voltage-reactive power control strategy, which contains a reactive power control delay compensation and a power command optimization based on the voltage time series prediction. The delay compensation is used to reduce the contribution of the untimely reactive power of wind turbines on transient overvoltage, and the power command optimization enables wind turbines to have the ability to regulate transient overvoltage, leading to the variation of AC voltage, thus suppressing the transient overvoltage. Finally, the effectiveness and feasibility of the proposed method are verified in a +/- 800kV/5000MW LCC-HVDC sending grid model based on MATLAB/Simulink.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [1] Transient AC Overvoltage Suppression Orientated Reactive Power Control of the Wind Turbine in the LCC-HVDC Sending Grid
    Bo Pang
    Xiao Jin
    Quanwang Zhang
    Yi Tang
    Kai Liao
    Jianwei Yang
    Zhengyou He
    CES Transactions on Electrical Machines and Systems, 2024, (02) : 152 - 161
  • [2] Overvoltage Suppression Strategy for Sending AC Grid With High Penetration of Wind Power in the LCC-HVdc System Under Commutation Failure
    Jin, Xiao
    Nian, Heng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (09) : 10265 - 10277
  • [3] A suppression method for sending-end transient overvoltage of LCC-HVDC based on the compensation of unbalanced reactive power and firing angle error
    Ouyang, Jinxin
    Tao, Rui
    Pan, Xinyu
    Xiao, Chao
    Guo, Chunyi
    Pang, Mingyu
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (24): : 53 - 63
  • [4] Transient overvoltage suppression of LCC-HVDC sending-end system based on DC current control optimisation
    Wang, Yang
    Zhu, Jianhang
    Li, Yingbiao
    Hu, Jiabing
    Ma, Shicong
    Wang, Tiezhu
    IET ENERGY SYSTEMS INTEGRATION, 2024, 6 (02) : 182 - 195
  • [5] Reactive power decentralized cooperative control method for restraining AC overvoltage of wind farm via LCC-HVDC grid-connected system
    Zhao D.
    Guo C.
    Ye Q.
    Fan X.
    Zhao Z.
    Li T.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (01): : 88 - 94
  • [6] Overvoltage Mechanism and Suppression Method for LCC-HVDC Rectifier Station Caused by Sending End AC Faults
    Liang, Wei
    Shen, Chen
    Sun, Huadong
    Xu, Shiyun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 1299 - 1302
  • [7] Commutation Overlap Characteristic Modeling and Stability Analysis of LCC-HVDC in Sending AC Grid
    Nian, Heng
    Liu, Yiming
    Li, Haipan
    Hu, Bin
    Liao, Yuming
    Yang, Jun
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2022, 13 (03) : 1594 - 1606
  • [8] Characteristic Description and Transient Overvoltage Suppression of Doubly-fed Wind Turbines with LCC-HVDC Commutation Failure
    Liu Q.
    Dong C.
    Wu Y.
    Zhang Y.
    Pang S.
    Shen J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (08): : 29 - 38
  • [9] An improved reactive power control strategy for LCC-HVDC to mitigate sending end transient voltage disturbance caused by commutation failures
    Xie, Qi
    Xiao, Xianyong
    Zheng, Zixuan
    Wang, Yang
    Song, Donghui
    Du, Kaijian
    Zou, Yi
    Zhang, Jiachen
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 146
  • [10] Quantitative calculation method and its overvoltage suppression strategy for sending-end transient voltage of LCC-HVDC under commutation failure
    Liu, Dong
    Li, Fangyuan
    Liu, Tianqi
    Zhang, Song
    Jiang, Shouqi
    ENERGY REPORTS, 2025, 13 : 3418 - 3429