Pilot protection for flexible HVDC transmission lines based on transient voltage ratio characteristics

被引:0
|
作者
Wang, Zhijie [1 ]
Li, Haifeng [1 ]
Jin, Haotian [1 ]
Liu, Hainan [1 ]
Liang, Yuansheng [1 ]
Wang, Gang [1 ]
机构
[1] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510641, Peoples R China
基金
中国国家自然科学基金;
关键词
Voltage waveform characteristics; Pilot protection; HVDC line; Standard deviation; SCHEME;
D O I
10.1016/j.ijepes.2024.110263
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To address the problems of poor speed performance and the large influence of the distributed capacitance of traditional pilot differential protection, a pilot protection scheme based on the characteristics of the transient voltage waveform is proposed. First, the expression of the relationship between the fault voltage of the currentlimiting reactor and the measuring point is derived. From the theoretical derivation, it can be inferred that for internal faults, the voltage ratio of the current-limiting reactor to the measuring point on both sides of the HVDC line is constant over a short period. For external faults, the voltage ratio of the current-limiting reactor to the measuring point varies exponentially on the fault side, while on the other side, it remains constant. Based on the above characteristics, the waveform characteristics of the voltage ratio of the current-limiting reactor to the measuring point are used to establish a protection criterion. A pilot protection scheme based on the standard deviation coefficient is proposed. The simulation results show that this method can reliably identify internal and external faults and has high sensitivity and selectivity. Moreover, this method is reliable for different types of faults and fault resistances. In addition, the proposed protection scheme can identify the type of fault in a short time window, requires a low sampling frequency, and does not require data synchronization.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Study on Multi-terminal flexible DC Pilot Line Protection Based on the Transient Voltages Amplitude Ratio and the Transient Current Characteristics
    Li Wei
    Li Zhongqing
    Zhang Yifan
    Cao Hong
    He Jiawei
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2860 - 2866
  • [42] Pilot Protection Based on Amplitude of Directional Travelling Wave for Voltage Source Converter-High Voltage Direct Current (VSC-HVDC) Transmission Lines
    Jiang, Lingtong
    Chen, Qing
    Huang, Wudi
    Wang, Lei
    Zeng, Yu
    Zhao, Pu
    ENERGIES, 2018, 11 (08)
  • [43] Transient Fault Location for HVDC Transmission Lines Based on Voltage Distribution and One-Terminal Information
    Li Bao-de
    Tan Jian-cheng
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [44] Single-end Protection Scheme Based on Transient Power Waveshape for Hybrid HVDC Transmission Lines
    Dai, Feiyang
    Zhou, Zexin
    Wang, Xingguo
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (05) : 1673 - 1686
  • [45] Single-end Protection Scheme Based on Transient Power Waveshape for Hybrid HVDC Transmission Lines
    Feiyang Dai
    Zexin Zhou
    Xingguo Wang
    Journal of Modern Power Systems and Clean Energy, 2023, 11 (05) : 1673 - 1686
  • [46] A Pilot Protection for LCC-HVDC Transmission Lines Based on Measured Surge Impedance at Tuning Frequency
    Liu, Ningning
    Li, Yongli
    Li, Song
    Li, Tao
    Yu, Lianke
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 2090 - 2103
  • [47] A novel pilot protection scheme for HVDC transmission lines based on waveform correlation analysis of traveling wave
    Kong, Fei
    Zhang, Baohui
    Wang, Yanting
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, 38 (20): : 108 - 114
  • [48] Traveling Wave Characteristics Based Pilot Protection Scheme for Hybrid Cascaded HVDC Transmission Line
    Dalin Mu
    Sheng Lin
    Xiaopeng Li
    Journal of Modern Power Systems and Clean Energy, 2024, (03) : 971 - 980
  • [49] Traveling Wave Characteristics Based Pilot Protection Scheme for Hybrid Cascaded HVDC Transmission Line
    Mu, Dalin
    Lin, Sheng
    Li, Xiaopeng
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2024, 12 (03) : 971 - 980
  • [50] Non-unit traveling wave protection for flexible HVDC lines based on the ratio of the waveform fitting residual
    Li, Haifeng
    Jiang, Huimin
    Liang, Yuansheng
    Xu, Yongzhi
    Wang, Gang
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 218