Seismic response of adjacent building structure connected with superelastic damper: Comparison with yield damper

被引:0
|
作者
Gur, Sourav [1 ]
Singh, Pranay [1 ]
Roy, Koushik [1 ]
机构
[1] Department of Civil and Environmental Engineering, Indian Institute of Technology (IIT) Patna, Bihta, Bihar,801103, India
关键词
Adjacent buildings - Adjacent structures - Building structure - Energy dissipation capacities - Floor accelerations - Seismic response control - Shape memory alloys(SMA) - Supplemental damping;
D O I
暂无
中图分类号
学科分类号
摘要
27
引用
收藏
页码:4696 / 4709
相关论文
共 50 条
  • [1] Seismic performance assessment of adjacent building structures connected with superelastic shape memory alloy damper and comparison with yield damper
    Gur, Sourav
    Roy, Koushik
    Singh, Pranay
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (05):
  • [3] Seismic response analysis of damper-connected adjacent structures with stochastic parameters
    Ge, Dong-dong
    Zhu, Hong-ping
    Wang, Dan-sheng
    Huang, Min-shui
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2010, 11 (06): : 402 - 414
  • [4] Seismic response analysis of damper-connected adjacent structures with stochastic parameters
    Dong-dong Ge
    Hong-ping Zhu
    Dan-sheng Wang
    Min-shui Huang
    Journal of Zhejiang University-SCIENCE A, 2010, 11 : 402 - 414
  • [5] Dynamic response of adjacent structures connected by friction damper
    Patel, C. C.
    Jangid, R. S.
    EARTHQUAKES AND STRUCTURES, 2011, 2 (02) : 149 - 169
  • [6] Harmonic response of adjacent structures connected with a friction damper
    Bhaskararao, A
    Jangid, RS
    JOURNAL OF SOUND AND VIBRATION, 2006, 292 (3-5) : 710 - 725
  • [7] Inelastic Seismic Response of Building with Friction Damper
    Banerjee S.
    Patro S.K.
    Journal of The Institution of Engineers (India): Series A, 2016, 97 (4) : 395 - 404
  • [8] Seismic response control of adjacent building by using hybrid control algorithm of MR damper
    Department of Architectural Engineering, Seoil University, Seoul, Korea, Republic of
    不详
    Procedia Eng., (1013-1020):
  • [9] Seismic Response Control of Adjacent Building by using Hybrid Control Algorithm of MR Damper
    Kim, G. C.
    Kang, J. W.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14 : 1013 - 1020
  • [10] FNCATB Superelastic damper for seismic vibration mitigation
    Bhowmick, Sutanu
    Mishra, Sudib Kumar
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2016, 27 (15) : 2062 - 2077