Observation of internal crack of steel bar by computed tomography and strain mapping near its tip using synchrotron white X-ray

被引:1
|
作者
Shibano, Jun-Ichi [1 ]
Kiriyama, Kouji [2 ]
Kajiwara, Kentaro [3 ]
Shobu, Takahisa [4 ]
Suzuki, Kenji [5 ]
Arai, Takayuki [6 ]
Miura, Setsuo [1 ]
Kobayashi, Michiaki [1 ]
机构
[1] Dept of Mech. Eng., Kitami Inst of Tech., Kitami, 090-8507, Kouen-cho
[2] Spring-8 Service Co., Ltd., Sayo-gun, Hyogo
[3] JASRI, Sayo-gun, Hyogo
[4] JAEA, Sayo-gun, Hyogo
[5] Dept of Tech. and Living Sci., Niigata Univ.
[6] Dept of Mech. Eng., Kitami Inst of Tech., Kouen-cho
关键词
Crack; CT; Energy dispersive method; High energy white X-ray; Strain mapping; Synchrotron radiation;
D O I
10.2472/jsms.58.596
中图分类号
学科分类号
摘要
Observation of the internal crack of steel by a computed tomography (CT) and strain mapping near its tip were investigated using a white X-ray obtained from BL28B2 beam line at SPring-8 in Japan. A low-alloy and high-tensile steel was used as a specimen prepared in the tensile bar with a parallel part of 5mm diameter. A fatigue crack was introduced into the specimen under the pulsating tension load (stress ratio R = 0). CT observation of the crack in the specimen was carried out by using the CCD camera that can detect indirectly the X-ray transmitted through the specimen. To measure the strain using the energy dispersive X-ray diffraction technique, the synchrotron white X-ray beam, which had a height of 100μm and a width of 100μm, was incident on the specimen with the Bragg angle θ of 5 degrees. As a result, the crack in the specimen under the tensile loading could be observed by the CT using the white X-ray. The resolution of CT, which was about 18μm 3, was considerably lower than it using a monochromatic X- ray reported previously. The large tensile strain was measured near the crack tip. It was, however, relatively small under the influence of the long slender gauge volume as compared with the crack tip distributed circularly. It was confirmed that the FWHM of diffracted X-ray profile measured near the crack tip was increased due to the steep change in the strain distribution. © 2009 The Society of Materials Science, Japan.
引用
收藏
页码:596 / 602
页数:6
相关论文
共 34 条
  • [31] Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study
    Matsubara, Kosuke
    Kawashima, Hiroki
    Kobayashi, Masanao
    Fukuda, Atsushi
    HEALTH AND TECHNOLOGY, 2020, 10 (06) : 1437 - 1443
  • [32] Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy
    Johnson, Quinton C.
    Kenesei, Peter
    Petruzza, Steve
    Plumb, Jayden
    Sharma, Hemant
    Park, Jun -Sang
    Marsden, Elliott
    Matheson, Kristoffer
    Czabaj, Michael W.
    Spear, Ashley D.
    MATERIALS CHARACTERIZATION, 2023, 195
  • [33] Investigation of Dark-Count-Less Lu2(SiO4)O-Multipixel-Photon Detector and Its Application to Photon Counting X-ray Computed Tomography Using Iodine Media
    Sato, Eiichi
    Oda, Yasuyuki
    Kodama, Hajime
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Osawa, Akihiro
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Kusachi, Shinya
    Sato, Shigehiro
    Ogawa, Akira
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (09)
  • [34] Low-Dose-Rate Computed Tomography System Utilizing 25 mm/s-Scan Silicon X-ray Diode and Its Application to Iodine K-Edge Imaging Using Filtered Bremsstrahlung Photons
    Matsushita, Ryo
    Sato, Eiichi
    Yanbe, Yutaka
    Chiba, Hiraku
    Maeda, Tomoko
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Osawa, Akihiro
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Kusachi, Shinya
    Sato, Shigehiro
    Ogawa, Akira
    Onagawa, Jun
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (03)