Observation of internal crack of steel bar by computed tomography and strain mapping near its tip using synchrotron white X-ray

被引:1
|
作者
Shibano, Jun-Ichi [1 ]
Kiriyama, Kouji [2 ]
Kajiwara, Kentaro [3 ]
Shobu, Takahisa [4 ]
Suzuki, Kenji [5 ]
Arai, Takayuki [6 ]
Miura, Setsuo [1 ]
Kobayashi, Michiaki [1 ]
机构
[1] Dept of Mech. Eng., Kitami Inst of Tech., Kitami, 090-8507, Kouen-cho
[2] Spring-8 Service Co., Ltd., Sayo-gun, Hyogo
[3] JASRI, Sayo-gun, Hyogo
[4] JAEA, Sayo-gun, Hyogo
[5] Dept of Tech. and Living Sci., Niigata Univ.
[6] Dept of Mech. Eng., Kitami Inst of Tech., Kouen-cho
关键词
Crack; CT; Energy dispersive method; High energy white X-ray; Strain mapping; Synchrotron radiation;
D O I
10.2472/jsms.58.596
中图分类号
学科分类号
摘要
Observation of the internal crack of steel by a computed tomography (CT) and strain mapping near its tip were investigated using a white X-ray obtained from BL28B2 beam line at SPring-8 in Japan. A low-alloy and high-tensile steel was used as a specimen prepared in the tensile bar with a parallel part of 5mm diameter. A fatigue crack was introduced into the specimen under the pulsating tension load (stress ratio R = 0). CT observation of the crack in the specimen was carried out by using the CCD camera that can detect indirectly the X-ray transmitted through the specimen. To measure the strain using the energy dispersive X-ray diffraction technique, the synchrotron white X-ray beam, which had a height of 100μm and a width of 100μm, was incident on the specimen with the Bragg angle θ of 5 degrees. As a result, the crack in the specimen under the tensile loading could be observed by the CT using the white X-ray. The resolution of CT, which was about 18μm 3, was considerably lower than it using a monochromatic X- ray reported previously. The large tensile strain was measured near the crack tip. It was, however, relatively small under the influence of the long slender gauge volume as compared with the crack tip distributed circularly. It was confirmed that the FWHM of diffracted X-ray profile measured near the crack tip was increased due to the steep change in the strain distribution. © 2009 The Society of Materials Science, Japan.
引用
收藏
页码:596 / 602
页数:6
相关论文
共 34 条
  • [1] Study on imaging and strain mapping in the vicinity of internal crack tip using synchrotron white X-ray
    Dept. of Mech. Eng., Kitami Inst. of Tech., Kouen-cho, Kitami, 090-8507, Japan
    不详
    不详
    不详
    不详
    Zairyo, 2008, 7 (667-673): : 667 - 673
  • [2] TRANSMISSION IMAGING AND STRAIN MAPPING IN THE VICINITY OF INTERNAL CRACK TIP USING SYNCHROTRON WHITE X-RAY
    Shibano, Jun-ichi
    Kajiwara, Kentaro
    Kiriyama, Koji
    Shobu, Takahisa
    Suzuki, Kenji
    Nishimura, Suguru
    Miura, Setsuo
    Kobayashi, Michiaki
    THERMEC 2009, PTS 1-4, 2010, 638-642 : 2476 - +
  • [3] High-resolution Observation of Steel Using X-ray Tomography Technique
    Toda, Hiroyuki
    Tomizato, Fukuto
    Zeismann, Frank
    Motoyashiki-Besel, Yasuko
    Uesugi, Kentaro
    Takeuchi, Akihisa
    Suzuki, Yoshio
    Kobayashi, Masakazu
    Brueckner-Foit, Angelika
    ISIJ INTERNATIONAL, 2012, 52 (03) : 516 - 521
  • [4] Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator
    Takeda, T
    Akiba, M
    Yuasa, T
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 685 - 695
  • [5] Measurement of internal strain in materials using high energy white X-ray at SPring-8
    Shibano, Jun-ichi
    Shobu, Takahisa
    Suzuki, Kenji
    Kiriyama, Koji
    Kajiwara, Kentaro
    Kaneko, Hiroshi
    Kobayashi, Michiaki
    STRESS EVALUATION IN MATERIALS USING NEUTRONS AND SYNCHROTRON RADIATION, 2008, 571-572 : 267 - +
  • [6] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268
  • [7] Minimal detectability of contrast materials in fluorescent x-ray computed tomography using synchrotron radiation
    Yu, Q
    Takeda, T
    Yuasa, T
    Hasegawa, Y
    Zeniya, T
    Hyodo, K
    Itai, Y
    Akatsuka, T
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 230 - 231
  • [8] Nanoscale in situ observations of crack initiation and propagation in carbon fiber/epoxy composites using synchrotron radiation X-ray computed tomography
    Watanabe, Toshiki
    Takeichi, Yasuo
    Niwa, Yasuhiro
    Hojo, Masaki
    Kimura, Masao
    COMPOSITES SCIENCE AND TECHNOLOGY, 2020, 197
  • [9] Experimental Approach for Clarifying Initiation and Growth Behaviors of Internal Fatigue Cracks Using Synchrotron Radiation Multiscale X-ray Computed Tomography
    Nakamura, Takashi
    Xue, Gaoge
    Kon, Yuma
    Fujimura, Nao
    Yamazaki, Takuya
    Tonozaki, Nobuyuki
    Takeuchi, Akihisa
    Uesugi, Masayuki
    Uesugi, Kentaro
    MATERIALS PERFORMANCE AND CHARACTERIZATION, 2023, 12 (02) : 107 - 128
  • [10] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088