Diagnosis of stator winding inter-turn short circuit in DFIG based on instantaneous average power in rotor side

被引:0
|
作者
Ma H. [1 ]
Zhang Y. [1 ]
Wei H. [1 ]
Fu M. [1 ]
Huang C. [1 ]
机构
[1] College of Energy and Electrical Engineering, Hohai University, Nanjing
来源
| 2018年 / Electric Power Automation Equipment Press卷 / 38期
基金
中国国家自然科学基金;
关键词
Doubly-fed induction generator; Multi-loop method; Rotor average instantaneous power spectrum; Spectrum analysis; Stator inter-turn short circuit;
D O I
10.16081/j.issn.1006-6047.2018.04.022
中图分类号
学科分类号
摘要
A method of stator winding inter-turn short circuit diagnosis for DFIGs(Doubly-Fed Induction Generators) is proposed due to the measurability of rotor parameters of DFIGs. With the consideration of high-order harmonic, the expressions of instantaneous rotor average power in conditions of normal and stator winding inter-turn short circuit are deduced, then the multi-loop mathematical model of DFIGs is established, and the simulation calculation of rotor ave-rage instantaneous power in conditions of normal and stator winding inter-turn short circuit in different degrees is carried out. The variation of harmonic component of instantaneous rotor average power is obtained by the spectrum analysis of simulative results, which verifies the correctness of theoretical analysis. The results also show that the rotor ave-rage instantaneous power spectrum is intuitional and simple, the 2nd-order harmonic components are not affected by slip ratio and the high-order harmonic components have strong sensitivity to stator winding inter-turn short circuit. © 2018, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:151 / 156
页数:5
相关论文
共 12 条
  • [1] Shu J., Zhang B., Li P., Et al., A control strategy on the variable-speed constant-frequency wind turbine, Automation of Electric Power Systems, 32, 16, (2008)
  • [2] Zhang H., Zhang Y., Yang D., Two-vectors-based model predictive direct power control of doubly fed induction gene-rator for grid connection and power regulation, Transactions of China Electrotechnical Society, 31, 5, pp. 69-76, (2016)
  • [3] Wan S., Li H., Xu Z., Et al., Analysis of generator vibration characteristic on stator winding inter-turn short circuit fault, Proceedings of the CSEE, 24, 4, pp. 161-165, (2004)
  • [4] Yazidi A., Capolino G.A., Casadei D., Et al., Simulation of dou-blefed induction machine for wind turbine generator fault analysis, 5th IEEE Symposium on Diagnostics for Electric Machine, pp. 1-6, (2005)
  • [5] Wei S., Fu Y., Ma H., Stator winding inter-turn short-circuit diagnosis and experimental research on doubly-fed wind generator, Power System Protection and Control, 38, 11, pp. 25-28, (2010)
  • [6] Li J., Wang D., He L., Steady-state analysis on inter-turn short circuit fault of stator windings in doubly-fed induction generators, Automation of Electric Power Systems, 37, 18, (2013)
  • [7] Shah D., Nandi S., Neti P., Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis, IEEE Transactions on Industry Application, 45, 5, pp. 1831-1842, (2009)
  • [8] Ma H., Zhang Z., Shi W., Doubly-fed induction generator stator fault diagnosis based on rotor instantaneous power spectrum, Automation of Electric Power Systems, 38, 14, pp. 30-35, (2014)
  • [9] Joksimovic G.M., Penman J., The detection of inter-turn short circuits in the stator windings of operating motors, IEEE Tran-sactions on Industrial Electronics, 47, 5, pp. 1078-1084, (2000)
  • [10] Nandi S., Space and time harmonics related problems and their mitigation for position and speed sensorless slipring induction motor drives application, Sadhana, 33, 5, pp. 565-580, (2008)