Comparative study of heat exchanger tubes failure analysis using ECT and IRIS

被引:0
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
Mughal, Mohammad Asghar [1 ]
Alamri, Yassir A. [2 ]
Alanazi, Mubarak A. [3 ]
机构
[1] Department of Mechanical Skills, Jubail Technical Institute, Royal Commission for Jubail and Yanbu, Jubail
[2] Mechanical Engineering Department, Jubail Industrial College, Royal Commission for Jubail and Yanbu, Jubail
[3] Electrical Engineering Department, Jubail Industrial College, Royal Commission for Jubail and Yanbu, Jubail
关键词
Eddy current testing; Heat exchanger; IRIS; Maintenance; NDT; Retubing; Tube inspection;
D O I
10.1007/s10751-024-02131-5
中图分类号
学科分类号
摘要
This article describes the comparative study of selected advanced tubing inspection nondestructive testing (NDT) methods of eddy current testing(ECT) & internal rotating inspection system (IRIS)for heat Exchanger equipment in the petrochemical industry. In this research tube material was SB 163 800 H (UNS 8810) and tubesheet material SB 564 800H (N08810). By utilizing two advanced tubing inspection methods of reporting, we can make adjustments to the process and extend the life of the heat exchanger by plugging tubes or retubing individual tubes or partial retubing or full retubing. The following data compares the suitability of ECT and IRIS for inspecting heat exchanger tubes. The capabilities of the considered NDT methods for tube inspections are presented in the study. Because of their high detectability and quick examination, nonferromagnetic materials like inconel should be tested by ECT. IRIS is ineffective on non-ferromagnetic materials like inconel based on experimentation and testing. © The Author(s), under exclusive licence to Springer Nature Switzerland AG 2024.
引用
收藏
相关论文
共 50 条
  • [1] Failure Analysis of Heat Exchanger Tubes
    Saffiudeen, Mohamed Fayas
    Syed, Abdullah
    Mohammed, Fasil T.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (03) : 1259 - 1264
  • [2] Failure Analysis of Heat Exchanger Tubes
    Mohamed Fayas Saffiudeen
    Abdullah Syed
    Fasil T. Mohammed
    Journal of Failure Analysis and Prevention, 2023, 23 : 1259 - 1264
  • [3] Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)
    Mohamed Fayas Saffiudeen
    Abdullah Syed
    Fasil T. Mohammed
    Journal of Failure Analysis and Prevention, 2023, 23 : 1898 - 1906
  • [4] Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)
    Saffiudeen, Mohamed Fayas
    Syed, Abdullah
    Mohammed, Fasil T.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (05) : 1898 - 1906
  • [5] Failure Analysis of Heat Exchanger Using Internal Rotary Inspection System (IRIS)
    Saffiudeen, Mohamed Fayas
    Syed, Abdullah
    Mohammed, Fasil T.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2021, 21 (02) : 494 - 498
  • [6] Failure Analysis of Heat Exchanger Using Internal Rotary Inspection System (IRIS)
    Mohamed Fayas Saffiudeen
    Abdullah Syed
    Fasil T. Mohammed
    Journal of Failure Analysis and Prevention, 2021, 21 : 494 - 498
  • [7] Failure analysis of heat exchanger tubes
    Usman, A.
    Khan, A. Nusair
    ENGINEERING FAILURE ANALYSIS, 2008, 15 (1-2) : 118 - 128
  • [8] Failure Analysis of Ethanol Vaporizer Heat Exchanger Tubes
    Sanders, S. A.
    Iwand, H. C.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (03) : 328 - 332
  • [9] Failure analysis of heat exchanger tubes of four gas coolers
    Allahkaram, S. R.
    Zakersafaee, P.
    Haghgoo, S. A. M.
    ENGINEERING FAILURE ANALYSIS, 2011, 18 (03) : 1108 - 1114
  • [10] A corrosion failure analysis of heat exchanger tubes operating in petrochemical refinery
    Rezaei, Milad
    Mahidashti, Zeynab
    Eftekhari, Sajad
    Abdi, Ehsan
    ENGINEERING FAILURE ANALYSIS, 2021, 119