Fluorescent aptasensors for sensitive detection of lead ions based on structure-switching DNA beacon probe and exonuclease I-mediated signal amplification

被引:1
|
作者
Su, Ruifang [1 ]
Li, Zhihong [1 ]
Yang, Chuanyu [1 ]
Li, Ying [1 ]
Wang, Junyang [1 ]
Sun, Chunyan [1 ,2 ]
机构
[1] Jilin Univ, Coll Food Sci & Engn, Dept Food Qual & Safety, Changchun 130062, Peoples R China
[2] Jilin Univ, Chongqing Res Inst, Chongqing 401123, Peoples R China
关键词
Beacon probe; Aptamer; Exonuclease I; Amplification; Fluorescence; Lead ion; G-QUADRUPLEX; STRANDED-DNA; APTAMER; PB2+; 2-AMINOPURINE; SENSOR; PRECONCENTRATION; MOLECULES; BIOSENSOR; ADSORBENT;
D O I
10.1016/j.saa.2024.124643
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Herein, two simple fluorescent signal-on sensing strategies for detecting lead ions (Pb2+) were established based on structure-switching aptamer probes and exonuclease-assisted signal amplification strategies. Two hairpin- structure fluorescent probes with blunt-ended stem arms were designed by extending the base sequence of Pb2+ aptamer (PS2.M) and labelling the probes with FAM (in probe 1) and 2-aminopurine (2-AP) (in probe 2), respectively. In method 1, graphene oxide (GO) was added to adsorb probe 1 and quench the fluorescence emission of FAM to achieve low fluorescent background. In method 2, fluorescent 2-AP molecule inserted into the double-stranded DNA of probe 2 was quenched as a result of base stacking interactions, leading to a simplified, quencher-free approach. The addition of Pb2+ can induce the probes to transform into G-quadruplex structures, exposing single DNA strands at the 3 ' end (the extended sequences). This exposure enables the activation of exonuclease I (Exo I) on the probes, leading to the cleavage effect and subsequent release of free bases and fluorophores, thereby resulting in amplified fluorescence signals. The two proposed methods exhibit good specificity and sensitivity, with detection limits of 0.327 nM and 0.049 nM Pb2+ for method 1 and method 2, respectively, and have been successfully applied to detect Pb2+ in river water and fish samples. Both detection methods employ the structure-switching aptamer probes and can be completed in two or three steps without the need for complex analytical instruments. Therefore, they have a broad prospect in the sensitive and simple detection of lead ion contamination in food and environmental samples.
引用
收藏
页数:9
相关论文
共 32 条
  • [1] Facile and sensitive detection of mercury ions based on fluorescent structure-switching aptamer probe and exonuclease III-assisted signal amplification
    Wang, Boxu
    Liu, Zheng
    Li, Zhihong
    Xu, Ningyi
    Zhang, Xuejiao
    Su, Ruifang
    Wang, Junyang
    Jin, Rui
    Sun, Chunyan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303
  • [2] Sensitive and Facile Detection of Vitamin D Based on Fluorescent Labeled Aptamer Probe and Exonuclease I-Assisted Signal Amplification
    Xu, Xinqiu
    Jia, Chaofan
    Zhang, Fengjiao
    Li, Hao
    Gong, Weilei
    Wang, Changqin
    Wei, Yin
    JOURNAL OF FLUORESCENCE, 2025,
  • [3] Sensitive detection for coralyne and mercury ions based on homo-A/T DNA by exonuclease signal amplification
    Huang, Hailiang
    Shi, Shuo
    Zheng, Xuyue
    Yao, Tianming
    BIOSENSORS & BIOELECTRONICS, 2015, 71 : 439 - 444
  • [4] An aptasensor for detection of potassium ions based on RecJf exonuclease mediated signal amplification
    Miao, Peng
    Tang, Yuguo
    Wang, Bidou
    Han, Kun
    Chen, Xifeng
    Sun, Haixuan
    ANALYST, 2014, 139 (22) : 5695 - 5699
  • [5] Highly sensitive fluorescent aptasensor for Salmonella paratyphi A via DNase I-mediated cyclic signal amplification
    Yan, Xing
    Li, Wenkai
    Liu, Keyi
    Deng, Le
    ANALYTICAL METHODS, 2015, 7 (24) : 10243 - 10250
  • [6] A simple lateral flow biosensor for rapid detection of lead(ii) ions based on G-quadruplex structure-switching
    Wang, Dou
    Ge, Chenchen
    Lv, Kongpeng
    Zou, Qingshuang
    Liu, Quan
    Liu, Liping
    Yang, Qinhe
    Bao, Shiyun
    CHEMICAL COMMUNICATIONS, 2018, 54 (97) : 13718 - 13721
  • [7] Label-Free Fluorescent Detection of Ions, Proteins, and Small Molecules Using Structure-Switching Aptamers, SYBR Gold, and Exonuclease I
    Zheng, Dongmei
    Zou, Ruxing
    Lou, Xinhui
    ANALYTICAL CHEMISTRY, 2012, 84 (08) : 3554 - 3560
  • [8] A DNAzyme-mediated signal amplification biosensor for ultrasensitive detection of lead ions based on SERS tags
    Teng, Wanqing
    Zhao, Jing
    Li, Qi
    Shi, Pengfei
    Zhang, Jing
    Yan, Mei
    Zhang, Shusheng
    SENSORS & DIAGNOSTICS, 2023, 2 (01): : 132 - 139
  • [9] Rolling Circle Amplification-based Polyvalent Molecular Beacon Probe for Signal-amplifying and Sensitive-Detection of Thrombin
    Zhang Zhiqing
    Wang Shanshan
    Zhang Zichen
    Ma Jie
    Wang Xiufeng
    Zhou Ting
    Wang Fang
    Zhang Guodong
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2019, 40 (12): : 2465 - 2470
  • [10] Engineering DNAzyme strategies for fluorescent detection of lead ions based on RNA cleavage-propelled signal amplification
    Li, Ying
    Liu, Kai
    Wang, Boxu
    Liu, Zheng
    Yang, Chuanyu
    Wang, Junyang
    Ma, Xinyue
    Li, Hongxia
    Sun, Chunyan
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 440