Insulation coordination of UHV half-wavelength AC transmission line

被引:0
|
作者
Peng, Qian [1 ]
Li, Shifeng [1 ]
机构
[1] State Nuclear Electric Power Planning Design and Research Institute, Haidian District, Beijing 100095, China
来源
关键词
D O I
10.13335/j.1000-3673.pst.2014.04.040
中图分类号
学科分类号
摘要
16
引用
收藏
页码:1082 / 1086
相关论文
共 50 条
  • [1] Adaptability Analysis of Differential Protection for UHV Half-wavelength AC Transmission Line
    Ma, Xiaowei
    Zhang, Ming
    Gao, Jiaxiong
    Wang, Qingping
    Bo, Zhiqian
    Zhao, Yingke
    Zhu, Yi
    Zheng, Hao
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [2] Steady state voltage characteristic of UHV half-wavelength AC transmission line
    Zhang, Zhiqiang
    Qin, Xiaohui
    Wang, Haohuai
    Xu, Zhengxiong
    Zhang, Dongxia
    Lin, Jiming
    Zheng, Jianchao
    Dianwang Jishu/Power System Technology, 2011, 35 (09): : 33 - 36
  • [3] Economic analysis and reliability assessment of UHV half-wavelength AC transmission
    Song, Yunting
    Zhou, Xiao
    Li, Bihui
    Zhang, Zhiqiang
    Zhang, Dongxia
    Qin, Xiaohui
    Lin, Jiming
    Han, Bin
    Dianwang Jishu/Power System Technology, 2011, 35 (09): : 1 - 6
  • [4] Travelling Wave Protection of UHV Half-wavelength AC Transmission Lines
    Zheng Y.
    Si X.
    Wu T.
    Yao G.
    Hong F.
    Zheng X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (18): : 124 - 131
  • [5] A Bergeron model based current differential protection principle for UHV half-wavelength AC transmission line
    Xiao, Shiwu
    Cheng, Yanjie
    Wang, Ya
    Dianwang Jishu/Power System Technology, 2011, 35 (09): : 46 - 50
  • [6] Integrated protection based on multi-frequency domain information for UHV half-wavelength AC transmission line
    Qingping Wang
    Zhiqian Bo
    Xiaowei Ma
    Ming Zhang
    Yingke Zhao
    Yi Zhu
    Lin Wang
    Protection and Control of Modern Power Systems, 2016, 1 (1)
  • [7] Integrated protection based on multi-frequency domain information for UHV half-wavelength AC transmission line
    Wang, Qingping
    Bo, Zhiqian
    Ma, Xiaowei
    Zhang, Ming
    Zhao, Yingke
    Zhu, Yi
    Wang, Lin
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2016, 1 (01)
  • [8] Power Transmission Capability and Transient Stability Influence Factors of UHV Half-Wavelength Transmission Line
    Wang A.
    Ren D.
    Tang Y.
    Yi J.
    Zhang J.
    1600, Power System Technology Press (41): : 3168 - 3173
  • [9] Characteristics of Transient Recovery Voltage of Circuit Breakers in UHV AC Half-wavelength Transmission System
    Wang P.
    Han B.
    Zhang Y.
    Xiang Z.
    Ban L.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (01): : 22 - 28
  • [10] Research on fault location for UHV half-wavelength transmission lines
    Wang, Guan
    Zhao, Haoran
    Hao, Qingshui
    China International Conference on Electricity Distribution, CICED, 2018, : 1341 - 1345