Development of pulsed wire field integral measurement system

被引:1
作者
Wang T. [1 ]
Jia Q. [1 ]
机构
[1] National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029
来源
Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams | 2010年 / 22卷 / 10期
关键词
Field integration; Insertion device; Magnetic measurement; Pulsed wire; Undulator;
D O I
10.3788/HPLPB20102210.2421
中图分类号
学科分类号
摘要
The theory and the devices of the pulsed wire magnetic measurement system are described. The effects on the measurement accuracy of wire gravity, noise and reflected signal are theoretically analyzed. Some methods such as symmetric wire mounting, night measuring and low-noise circuit design are proposed for optimizing various components of the device to reduce the effects. The results of magnetic measurement of the pulsed wire system are compared with that of Hall probe method. It is applied to measure the practical electromagnetic undulator to be put to use in National Synchrotron Radiation Laboratory and verify the current relationship between the correction coils and main coils.
引用
收藏
页码:2421 / 2424
页数:3
相关论文
共 8 条
  • [1] Warren R.W., Elliott C.J., A new system for wiggler fabrication and testing, Conference on Undulator Magnets for Synchrotron Radiation and Free Electron Lasers, (1987)
  • [2] Warren R.W., Limitations on the use of the pulsed wire field measuring technique, Nucl Instr and Meth A, 272, pp. 257-263, (1988)
  • [3] Preston D.W., Warren R.W., Wiggler field measurements and corrections using the pulsed wire technique, Nucl Instr and Meth A, 318, pp. 794-797, (1992)
  • [4] Varfolomeev A.A., Bouzouloukov Y.P., Ivanchenkov S.N., Et al., Wire method for magnetic field measurements in long undulators, Nucl Instr and Meth, 359, pp. 93-96, (1995)
  • [5] Varfolomeev A.A., Khlebnikov A.S., Osmanov N.S., Et al., Improved wire deflection method for magnetic field measurements in long undulators, Nucl Instr and Meth, 358, pp. 46-47, (1995)
  • [6] Qu T., Liu Q., Zhou C., Experimental investigation of pulsed wire magnetic field measurement method, High Power Laser and Particle Beams, 7, 2, pp. 165-170, (1995)
  • [7] Li Y., Yan H., Zhou Q., Development of a pulsed wire system for undulator measurement, Nuclear Technique, 30, 10, pp. 815-817, (2007)
  • [8] Corlier M., Besson J.C., Brunelle P., Et al., Performances of OPHELIE: a new type of undulator at LURE, IEEE Trans on Applied Superconductivity, 10, 1, pp. 240-243, (2000)