Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas

被引:0
|
作者
Redwine, Jarah S. [1 ]
Lacey, Ronald E. [1 ,3 ]
Mukhtar, Saqib [1 ]
Carey, John B. [2 ]
机构
[1] Dept. of Biol./Agric. Engineering, Texas A and M University, College Station, TX, United States
[2] Department of Poultry Science, Texas A and M University, College Station, TX, United States
[3] Texas A and M University, 201 Scoates Hall, MS2117, College Station, TX 77843, United States
来源
Transactions of the American Society of Agricultural Engineers | 2002年 / 45卷 / 04期
关键词
Ammonia; -; Concentration; (process); Ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
Total suspended particulate (TSP) concentrations, ammonia (NH3) concentrations, and ventilation rates were measured in four commercial, tunnel-ventilated broiler houses in June through December of 2000 in Brazos County, Texas. TSP and NH3 concentrations ranged from 7,387 to 11,387 μg m-3 and 2.02 to 45 ppm, respectively. Ammonia concentration exhibited a correlation with the age of the birds. Mass median diameters (MMD) of the TSP samples were between 24.0 and 26.7 μm aerodynamic equivalent diameter. MMD increased with bird age. The mass fraction of PM10 in the TSP samples was between 2.72% and 8.40% with a mean of 5.94%. Ventilation rates were measured between 0.58 and 89 m3 s-1. Measured concentrations of PM10 and ammonia were multiplied by the measured ventilation rates to calculate emission rates for PM10 and ammonia. Ammonia emission rates varied from 38 to 2105 g hr-1. TSP emission rates and PM10 emission rates ranged from 7.0 to 1673 g hr-1 and 0.58 to 99 g hr-1, respectively. Emission rates for ammonia and particulate matter increased with the age of the birds. Most of the PM in the commercial broiler houses was large enough to be captured by the human or poultry respiratory system prior to being inhaled into the lungs.
引用
收藏
页码:1101 / 1109
相关论文
共 41 条
  • [1] Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas
    Redwine, JS
    Lacey, RE
    Mukhtar, S
    Carey, JB
    TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 1101 - 1109
  • [2] Ammonia Emissions in Tunnel-Ventilated Broiler Houses
    Lima, K. A. O.
    Moura, D. J.
    Carvalho, T. M. R.
    Bueno, L. G. F.
    Vercellino, R. A.
    BRAZILIAN JOURNAL OF POULTRY SCIENCE, 2011, 13 (04) : 265 - 270
  • [3] Managemental Impacts on Particulate Matter Emission in Tunnel-Ventilated Broiler Houses
    Seo, Hyo-Jae
    Seo, Il-Hwan
    Oh, Byung-Wook
    AGRICULTURE-BASEL, 2024, 14 (02):
  • [4] Particulate matter and ammonia emission factors for tunnel-ventilated broiler production houses in the Southern US
    Lacey, RE
    Redwine, JS
    Parnell, CB
    TRANSACTIONS OF THE ASAE, 2003, 46 (04): : 1203 - 1214
  • [5] Comparison of ammonia measurement methods inside and outside tunnel-ventilated broiler houses
    Hale, B. D.
    Fairchild, B.
    Worley, J.
    Harper, L.
    Ritz, C.
    Czarick, M.
    Rathbun, S. L.
    Irvin, E. A.
    Naeher, L. P.
    JOURNAL OF APPLIED POULTRY RESEARCH, 2010, 19 (03): : 245 - 262
  • [6] Concentration and particle size distribution of particulate matter inside tunnel-ventilated high-rise layer operation houses
    Wang-Li, Lingjuan
    Cao, Zihan
    Li, Qianfeng
    Liu, Zifei
    Beasley, David B.
    ATMOSPHERIC ENVIRONMENT, 2013, 66 : 8 - 16
  • [7] Fine particle measurements inside and outside tunnel-ventilated broiler houses
    Visser, M. C.
    Fairchild, B.
    Czarick, M.
    Lacy, M.
    Worley, J.
    Thompson, S.
    Kastner, J.
    Ritz, C.
    Naeher, L. P.
    JOURNAL OF APPLIED POULTRY RESEARCH, 2006, 15 (03): : 394 - 405
  • [8] EFFECT OF AIR DEFLECTORS ON FAN PERFORMANCE IN TUNNEL-VENTILATED BROILER HOUSES WITH A DROPPED CEILING
    Purswell, J. L.
    Luck, B. D.
    Davis, J. D.
    APPLIED ENGINEERING IN AGRICULTURE, 2014, 30 (03) : 471 - 475
  • [9] Effect of air deflectors on fan performance in tunnel-ventilated broiler houses with a dropped ceiling
    Purswell, J.L. (joseph.purswell@ars.usda.gov), 1600, American Society of Agricultural and Biological Engineers (30):
  • [10] Dust emissions from a tunnel-ventilated broiler poultry shed with fresh and partially reused litter
    Modini, Robin L.
    Agranovski, Victoria
    Meyer, N. K.
    Gallagher, Erin
    Dunlop, Mark
    Ristovski, Zoran D.
    ANIMAL PRODUCTION SCIENCE, 2010, 50 (5-6) : 552 - 556