Spleen stiffness and splenoportal venous flow: Assessment before and after transjugular intrahepatic portosystemic shunt placement

被引:0
作者
机构
[1] Institute of Ultrasound Imaging, Second Affiliated Hospital, Chongqing Medical University, Chongqing
[2] Department of Infectious Diseases, Second Affiliated Hospital, Chongqing Medical University, Chongqing
[3] Department of Radiology, New York-Presbyterian Hospital, Weill Cornell Medical College, New York, NY 10065, 525 E 68th St
来源
Gao, J. (jig2001@med.cornell.edu) | 1600年 / John Wiley and Sons Ltd卷 / 32期
关键词
Color Doppler sonography; Elastography; Portal hypertension; Shear wave velocity; Spleen;
D O I
10.7863/jum.2013.32.2.221
中图分类号
学科分类号
摘要
Objectives-To prospectively assess changes in spleen stiffness and splenoportal venous flow before and after transjugular intrahepatic portosystemic shunt (TIPS) placement. Methods-We prospectively evaluated spleen stiffness measured by the mean shear wave velocity with acoustic radiation force impulse imaging and the splenoportal venous velocity with color Doppler sonography in 12 patients (mean age ± SD, 42.6 ± 11.0 years; range, 29-65 years) who underwent TIPS placement for portal hypertension and gastroesophageal bleeding. The mean shear wave velocity and angle-corrected splenoportal venous velocity at the main portal and splenic veins were measured 1 day before and 3 to 9 days after TIPS placement (mean interval, 6.0 ± 1.95 days; range, 4-10 days) and were compared with portal vein pressure measured during the procedure. Results-There was a significant difference in portal vein pressure before and after TIPS (25.34 ± 6.21 versus 15.66 ± 6.07 mm Hg; P = .0005). After TIPS, the mean shear wave velocity decreased significantly in all 12 cases (3.50 ± 0.46 versus 3.15 ± 0.39 m/s before and after TIPS; P = .00015). The flow velocity at the main portal vein increased significantly after TIPS (22.21 ± 4.13 versus 47.25 ± 12.37 cm/s; P = .0000051). The splenic vein velocity and spleen index measured 25.57 ± 6.98 cm/s and 55.99 ± 21.27 cm2, respectively, before TIPS and 35.72 ± 11.10 cm/s and 50.11 ± 21.12 cm2 after TIPS (P = .0004 and .003). Conclusions-A significant decrease in the mean shear wave velocity and increase in the splenoportal venous velocity occurred with reduced portal vein pressure after TIPS placement. Hence, both parameters can be used as noninvasive quantitative markers for monitoring TIPS function after placement. Copyright © 2013 by the American Institute of Ultrasound in Medicine.
引用
收藏
页码:221 / 228
页数:7
相关论文
共 24 条
[1]  
Colombato L., The role of transjugular intrahepatic portosystemic shunt (TIPS) in the management of portal hypertension, J Clin Gastroenterol, 41, SUPPL. 3, (2007)
[2]  
De Franchis R., Dell'era A., Primignani M., Diagnosis and monitoring of portal hypertension, Dig Liver Dis, 40, pp. 312-317, (2008)
[3]  
Kutlu R., Karaman I., Akbulut A., Et al., Quantitative Doppler evaluation of the splenoportal venous system in various stages of cirrhosis: Differences between right and left portal veins, J Clin Ultrasound, 30, pp. 537-543, (2002)
[4]  
Middleton W.D., Teefey S.A., Darcy M.D., Doppler evaluation of transjugular intrahepatic portosystemic shunts, Ultrasound Q, 19, pp. 56-70, (2003)
[5]  
Foshager M.C., Ferral H., Nazarian G.K., Castaneda-Zuniga W.R., Letourneau J.G., Duplex sonography after transjugular intrahepatic portosystemic shunt (TIPS): Normal hemodynamic findings and efficacy in predicting shunt patency and stenosis, AJR Am J Roentgenol, 165, pp. 1-7, (1994)
[6]  
Martinez-Noguera A., Montserrat E., Torrubia S., Villalba J., Doppler in hepatic cirrhosis and chronic hepatic, Semin Ultrasound CT MR, 23, pp. 19-36, (2002)
[7]  
Wachsberg R.H., Doppler ultrasound evaluation of transjugular intrahepatic portosystemic shunt function: Pitfalls and artifacts, Ultrasound Q, 19, pp. 139-148, (2003)
[8]  
Goyal N., Jain N., Rachapalli V., Cochlin D.L., Robinson M., Non-invasive evaluation of liver cirrhosis using ultrasound, Clin Radiol, 64, pp. 1056-1066, (2009)
[9]  
Hirooka M., Ochi H., Koizumi Y., Et al., Splenic elasticity measured with renal-time tissue elastography is a marker of portal hypertension, Radiology, 261, pp. 960-968, (2011)
[10]  
Stefanescu H., Grigorescu M., Lupsor M., Procopet B., Maniu A., Badea R., Spleen stiffness measurement using fibroscan for the noninvasive assessment of esophageal varices in liver cirrhosis patients, J Gastroenterol Hepatol, 26, pp. 164-170, (2010)