Study on 3D printing a fine quality bone-mimetic porous structure with minimized shape error in pore size: a parametric work on key laser parameters in SLM

被引:1
作者
Ban, Hun Yeong [1 ,2 ]
Choi, Seong-Won [3 ]
Jung, Tae-Gon [4 ]
Park, Jong-Chul [1 ]
Lim, Dohyung [2 ,5 ]
机构
[1] Yonsei Univ, Coll Med, Dept Med Engn, Seoul, South Korea
[2] Sejong Univ, Dept Mech Engn, Seoul, South Korea
[3] Chonnam Natl Univ Hosp, Ind Support Ctr Convergence Med Devices, Gwangju, South Korea
[4] Osong Med Innovat Fdn, Cheongju, South Korea
[5] RNX Inc, Bucheon, South Korea
关键词
3D printing; Selective laser melting; Bone-mimetic porous structure; Parametric study; Shape error; Mechanical properties; POWDER BED FUSION; IN-VITRO; SCAFFOLDS; FABRICATION; POROSITY; BEHAVIOR; CELLS;
D O I
10.1007/s00170-024-14729-8
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One current trend in orthopedics is the production of bone-mimetic porous structures using selective laser melting (SLM). However, there is still a lack of knowledge on fine-tuning the process to ensure the quality of such complex products. Therefore, this study sought to gain insight into how the laser parameters affect the pore shape and mechanical properties. Specifically, based on Voronoi tessellation, the bone-mimetic porous structure was designed to have an average pore size of 600 mu m and fabricated by an SLM machine using Ti-6Al-4 V powder. The laser power and scan speed varied at 80-160 W and 550-950 mm/s, respectively. Afterward, the pore shape error was manually measured using micro-CT images, and the mechanical properties were obtained through compression tests. As a result, the pore narrowed in response to stronger laser powers and slower scan speeds, more dominantly altered by the former. In addition, greater dimensional inaccuracies led to higher mechanical properties, showing a positive correlation. Consequently, the combination of the weakest laser power (80 W) and the fastest scan speed (950 mm/s) exhibited the closest pore size distribution to the design with minimized shape errors of 135-150 mu m while maintaining clinically acceptable levels of compressive strength and elastic modulus (131.45 MPa and 6.24 GPa, respectively). Our findings can serve as valuable references for successfully manufacturing the latest porous implants.
引用
收藏
页码:4577 / 4594
页数:18
相关论文
共 63 条
[1]   Titanium-Based alloys and composites for orthopedic implants Applications: A comprehensive review [J].
Abd-Elaziem, Walaa ;
Darwish, Moustafa A. ;
Hamada, Atef ;
Daoush, Walid M. .
MATERIALS & DESIGN, 2024, 241
[2]   Review of selective laser melting of magnesium alloys: advantages, microstructure and mechanical characterizations, defects, challenges, and applications [J].
Ahmadi, M. ;
Tabary, S. A. A. Bozorgnia ;
Rahmatabadi, D. ;
Ebrahimi, M. S. ;
Abrinia, K. ;
Hashemi, R. .
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 19 :1537-1562
[3]   Osteoinduction, osteoconduction and osseointegration [J].
Albrektsson, T ;
Johansson, C .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S96-S101
[4]   Printability and geometric capability of L-PBF in manufacturing thin circular cross-sections [J].
Arputharaj, John Daniel ;
Nafisi, Shahrooz ;
Ghomashchi, Reza .
JOURNAL OF MANUFACTURING PROCESSES, 2024, 129 :319-340
[5]   Lattice structures in stainless steel 17-4PH manufactured via selective laser melting (SLM) process: dimensional accuracy, satellites formation, compressive response and printing parameters optimization [J].
Bertocco, Alcide ;
Iannitti, Gianluca ;
Caraviello, Antonio ;
Esposito, Luca .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 120 (7-8) :4935-4949
[6]   Effect of Cell Wall Ductility and Toughness on Compressive Response and Strain Rate Sensitivity of Aluminium Foam [J].
Byakova, Alexandra ;
Gnyloskurenko, Svyatoslav ;
Vlasov, Andrey ;
Semenov, Nikolay ;
Yevych, Yan ;
Zatsarna, Oleksandra ;
Danilyuk, Vladimir .
ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
[7]   Dimensional Errors Due to Overhanging Features in Laser Powder Bed Fusion Parts Made of Ti-6Al-4V [J].
Charles, Amal ;
Elkaseer, Ahmed ;
Thijs, Lore ;
Scholz, Steffen G. .
APPLIED SCIENCES-BASEL, 2020, 10 (07)
[8]   Choosing between commercially pure titanium and Ti-6Al-4V gyroid structures for orthopedic applications: An analysis through Timoshenko beam theory, the Gibson-Ashby model and experimental methods [J].
Depboylu, Fatma Nur ;
Yasa, Evren ;
Poyraz, Ozgur ;
Korkusuz, Feza ;
Popa, Andrei- Alexandru .
MATERIALS TODAY COMMUNICATIONS, 2024, 39
[9]   Titanium based bone implants production using laser powder bed fusion technology [J].
Depboylu, Fatma Nur ;
Yasa, Evren ;
Poyraz, Ozgur ;
Minguella-Canela, Joaquim ;
Korkusuz, Feza ;
De los Santos Lopez, M. Antonia .
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 17 :1408-1426
[10]   A modified volumetric energy density-based approach for porosity assessment in additive manufacturing process design [J].
Ferro, Paolo ;
Meneghello, Roberto ;
Savio, Gianpaolo ;
Berto, Filippo .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2020, 110 (7-8) :1911-1921