Research on power frequency transient overvoltage in 1000kV UHV AC transmission line

被引:0
|
作者
Chen, Shui-Ming [1 ]
Xu, Wei [1 ]
He, Jin-Liang [1 ]
机构
[1] State Key Lab. of Control and Simulation of Power Systems and Generation Equipments, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing 100084, China
关键词
Computer simulation - Electric insulation - Electric load shedding - Electric potential - Electric power systems - Electric power transmission;
D O I
暂无
中图分类号
学科分类号
摘要
Against the background of a single circuit UHV power transmission project in one million voltage from Jincheng to Jingzhou via Nanyang that is reasoned by State Power Grid Corp. of China, its power frequency overvoltages in three operating conditions, i.e., capacity effect of unloaded line, unsymmetrical faults and load shedding, are researched, and the measures to eliminate power frequency voltage rising such as using high voltage reactor to compensate reactive power are put forward. Simulation results show that the maximum power frequency voltage rising caused by capacity effect in unloaded line, single-phase earth fault and load shedding are 1.04 per unit, 1.31 per unit and 1.20 per unit respectively. Under load shedding and unsymmetrical earth fault, the effect of eliminating power frequency voltage rising is better when parallel high voltage reactor is installed at the receiving end of transmission line but not at the sending end or at both ends.
引用
收藏
页码:1 / 5
相关论文
共 50 条
  • [31] A distance protection relay for a 1000-kV UHV transmission line
    Xu, Z. Y.
    Huang, S. F.
    Ran, Li
    Liu, J. F.
    Qin, Y. L.
    Yang, Q. X.
    He, J. L.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1795 - 1804
  • [32] Study on Transient Characteristics and its Impact on Protection of 1000kV Transmission Line Based on Marti Model
    Qiao, Yan
    Qing, Chen
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [33] Impact of transmission line parameters on harmonic transmission coefficients in 1000 kV AC power transmission system
    Liu, Shu-Ming
    Xu, Yong-Hai
    Zhu, Yong-Qiang
    Xiao, Xiang-Ning
    Dianwang Jishu/Power System Technology, 2010, 34 (01): : 11 - 14
  • [34] Modeling and Simulation Analysis of Power Frequency Electric Field of UHV AC Transmission Line
    Han, Chen
    Chen, Yuchen
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2015, 6 (01) : 77 - 81
  • [35] Power frequency and switching overvoltages of 750 kV AC transmission line
    Liu, Qing
    Zhang, Yu-Feng
    Wan, Geng
    Shi, Wei
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (06): : 1338 - 1343
  • [36] Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line
    Sun, Guanqun
    Ma, Wang
    Wang, Yingge
    Xu, Dian
    Liu, Haiguang
    Chen, Rusi
    Ding, Yixing
    ELECTRONICS, 2025, 14 (03):
  • [37] FORCED EXTINCTION CHARACTERISTICS OF SECONDARY ARC ON UHV (1000KV CLASS) TRANSMISSION-LINES
    GODA, Y
    MATSUDA, S
    INABA, T
    OZAKI, Y
    MOUSA, AM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1322 - 1330
  • [38] Measurement of TEV of 1000kV UHV Gas Insulated Switchgear
    Zhao, Jun
    Zhang, Jiangong
    Liu, Zhenhuan
    Gan, Zheyuan
    2015 7TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS (CEEM), 2015, : 313 - 315
  • [39] Study of Nonlinear Model of Shunt Reactor in 1000kV AC Transmission System
    Yue Hao
    Xu Yonghai
    Liu Yingying
    Zhu Yongqiang
    Xiao Xiangning
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 305 - 308
  • [40] Statistical Switching Overvoltages of 1200 kV UHV AC Transmission Line
    Annadi R.R.
    Patsa C.S.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) : 189 - 195