High power laser multi-parameter measurement technique based on integrating sphere

被引:0
作者
Chen X. [1 ,2 ]
Tang S. [1 ]
Hui H. [1 ,2 ]
Liu D. [1 ]
Ouyang X. [1 ]
Lin Q. [1 ]
Zhu B. [1 ]
机构
[1] National Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai
[2] University of Chinese Academy of Sciences, Beijing
来源
Zhongguo Jiguang/Chinese Journal of Lasers | 2016年 / 43卷 / 08期
关键词
Beam-splitter; Integrating sphere; Measurement; Modular design; Monte-Carlo method;
D O I
10.3788/CJL201643.0804002
中图分类号
学科分类号
摘要
Aiming at the disadvantage that the traditional measurement technique is sensitive to the incident direction of incident light, a beam-split technique of high power laser multi-parameter measurement based on integrating sphere is proposed. Numerical analysis and simulation about attenuation rate, time waveform of emergent light, and time waveform recovery of incident light are carried out by Monte-Carlo method, which validate the feasibility that the integrating sphere can be used as beam-splitter in laser measurement system. The energy and time waveform of nanosecond laser is measured based on integrating sphere. The theoretical analysis matches well with the experiment result. Experiment and simulation results show that spectrum parameter, energy parameter and time parameter of incident light can be recovered by measuring the parameters of the emergent light, when the light-split technique is used in laser parameters measurement. The proposed technique can conquer the disadvantage that the incident direction of incident light has great influence on the parameters of the emergent light in traditional technique. The proposed technical proposal possesses small volume and is easy to integrate, which can be used in modular design of multiple beam high power laser parameters measurement system. © 2016, Chinese Lasers Press. All right reserved.
引用
收藏
页数:9
相关论文
共 13 条
[1]  
Haynam C.A., Wegner P.J., Auerbach J.M., Et al., National ignition facility laser performance status, Applied Optics, 46, 16, pp. 3276-3303, (2007)
[2]  
Liu D., Xu R., Fan D., Study of cavity mirror alignment in multi-pass amplifier, High Power Laser and Particle Beams, 16, 9, pp. 1161-1165, (2004)
[3]  
Zeng P., Liu D., Peng Z., Et al., Research of auto-alignment system based on ethernet, Chinese J Lasers, 41, 3, (2014)
[4]  
Ouyang X., Yang L., Peng Y., Et al., Analysis on reliability of diagnostics system for picosecond petawatt laser, Chinese J Lasers, 40, 1, (2013)
[5]  
Boyd R.D., Bliss E.S., Boege S.J., Et al., Alignment and diagnostics of the national ignition facility laser system, SPIE, 3782, pp. 496-501, (1999)
[6]  
Burkhart S.C., Smith I., Beamlet laser diagnostics, Distribution Category, (1994)
[7]  
Wang H., Wu B., Liu H., Et al., Radiation uniformity calibration method of integrating sphere with large aperture, Acta Optica Sinica, 33, (2013)
[8]  
Sun J., Zhang H., Thermal design for a kind of high-light-level integrating sphere calibration source, Acta Optica Sinica, 35, 3, (2015)
[9]  
Goebel D.G., Generalized integrating-sphere theory, Applied Optics, 6, 1, pp. 125-128, (1967)
[10]  
Gao X., Zhou D., Zhou S., Et al., Transformation theory of light power waveform by an integrating sphere, Acta Optica Sinica, 22, 4, pp. 465-469, (2002)