Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis

被引:2
|
作者
Jin, Weiyi [1 ]
Yang, Siyu [1 ]
Yin, Longlong [2 ]
Jia, Yeqing [1 ]
Li, Xinghua [1 ]
An, Kang [3 ]
Li, Jianping [1 ]
Zhang, Yi [1 ]
机构
[1] Tianjin Ctr Dis Control & Prevent, Inst Hlth Inspection & Testing, 6 Huayue Rd, Tianjin 300011, Peoples R China
[2] Shandong Ctr Dis Control & Prevent, Jinan, Peoples R China
[3] Shandong First Med Univ Shandong Acad Med Sci, Sch Publ Hlth & Hlth Adm, 6699 Qingdao Rd, Jinan 250021, Shandong, Peoples R China
关键词
Bisphenol analogues; 96-well SPE; UHPLC-MS/MS; MRM-IDA-EPI; Urine;
D O I
10.1016/j.chroma.2024.465096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using beta-glucuronidase in an ammonium acetate buffer solution at 37 degrees C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 mu g center dot kg-1- 1 to 0.3 mu g kg- 1 . Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Ultra-high performance liquid chromatography-tandem mass spectrometry for the quantification of icaritin in mouse bone
    Zhang, Shuang-Qing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 978 : 24 - 28
  • [42] Determination of Free Fatty Acids in Cheese by Means of Matrix Solid-Phase Dispersion Followed by Ultra-High Performance Liquid Chromatography and Tandem Mass Spectrometry Analysis
    Simeoni, Maria Chiara
    Sergi, Manuel
    Pepe, Alessia
    Mattocci, Enrico
    Martino, Giuseppe
    Compagnone, Dario
    FOOD ANALYTICAL METHODS, 2018, 11 (10) : 2961 - 2968
  • [43] Determination of Free Fatty Acids in Cheese by Means of Matrix Solid-Phase Dispersion Followed by Ultra-High Performance Liquid Chromatography and Tandem Mass Spectrometry Analysis
    Maria Chiara Simeoni
    Manuel Sergi
    Alessia Pepe
    Enrico Mattocci
    Giuseppe Martino
    Dario Compagnone
    Food Analytical Methods, 2018, 11 : 2961 - 2968
  • [44] Analysis of ethenoguanine adducts in human urine using high performance liquid chromatography-tandem mass spectrometry
    Gonzalez-Reche, LM
    Koch, HM
    Weiss, T
    Müller, J
    Drexler, H
    Angerer, J
    TOXICOLOGY LETTERS, 2002, 134 (1-3) : 71 - 77
  • [45] High-throughput biomonitoring of organophosphate flame-retardant metabolites in urine via 96-blade solid-phase microextraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry
    Jing, Yu
    Singh, Varoon
    Chen, Liqin
    Pawliszyn, Janusz
    TALANTA, 2021, 232
  • [46] Generic Methods for Simultaneous Analysis of Four Direct Oral Anticoagulants in Human Plasma and Urine by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ren, Jian-Wei
    Zheng, Xin
    Han, Xiao-Hong
    MOLECULES, 2023, 28 (05):
  • [47] Trace determination of antibacterial pharmaceuticals in fishes by microwave-assisted extraction and solid-phase purification combined with dispersive liquid-liquid microextraction followed by ultra-high performance liquid chromatography-tandem mass spectrometry
    Huang, Peiting
    Zhao, Pan
    Dai, Xinpeng
    Hou, Xiaohong
    Zhao, Longshan
    Liang, Ning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1011 : 136 - 144
  • [48] Multiclass analysis of 25 veterinary drugs in milk by ultra-high performance liquid chromatography-tandem mass spectrometry
    Li, Juan
    Ren, Xueling
    Diao, Yanyan
    Chen, Yu
    Wang, Qingli
    Jin, Wenting
    Zhou, Piao
    Fan, Qiqi
    Zhang, Yanbing
    Liu, Hongmin
    FOOD CHEMISTRY, 2018, 257 : 259 - 264
  • [49] Simultaneous determination of four mercapturic acids in human urine using solid phase extraction and liquid chromatography-tandem mass spectrometry
    Hou Hongwei
    Xiong Wei
    Gao Na
    Song Dongkui
    Tang Gangling
    Hu Qingyuan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (01) : 31 - 35
  • [50] A rapid method for the determination of mycotoxins in edible vegetable oils by ultra-high performance liquid chromatography-tandem mass spectrometry
    Hidalgo-Ruiz, Jose L.
    Romero-Gonzalez, Roberto
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    FOOD CHEMISTRY, 2019, 288 (22-28) : 22 - 28