Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis

被引:2
|
作者
Jin, Weiyi [1 ]
Yang, Siyu [1 ]
Yin, Longlong [2 ]
Jia, Yeqing [1 ]
Li, Xinghua [1 ]
An, Kang [3 ]
Li, Jianping [1 ]
Zhang, Yi [1 ]
机构
[1] Tianjin Ctr Dis Control & Prevent, Inst Hlth Inspection & Testing, 6 Huayue Rd, Tianjin 300011, Peoples R China
[2] Shandong Ctr Dis Control & Prevent, Jinan, Peoples R China
[3] Shandong First Med Univ Shandong Acad Med Sci, Sch Publ Hlth & Hlth Adm, 6699 Qingdao Rd, Jinan 250021, Shandong, Peoples R China
关键词
Bisphenol analogues; 96-well SPE; UHPLC-MS/MS; MRM-IDA-EPI; Urine;
D O I
10.1016/j.chroma.2024.465096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using beta-glucuronidase in an ammonium acetate buffer solution at 37 degrees C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 mu g center dot kg-1- 1 to 0.3 mu g kg- 1 . Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Application of Solid-Phase Extraction for the Quantification of Urinary AICAR by Ultra-High Performance Liquid Chromatography–Tandem Mass-Spectrometry
    E. V. Dmitrieva
    A. Z. Temerdashev
    A. A. Azaryan
    E. M. Gashimova
    Journal of Analytical Chemistry, 2019, 74 : 861 - 864
  • [22] Determination of nine phthalate ester metabolites in human urine using ultra high performance liquid chromatography-tandem triple quadrupole mass spectrometry
    Zhang Xu
    Qiu Tian
    Fu Hui
    Yang Yanwei
    Zhao Feng
    Lin Shaobin
    Hu Xiaojian
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (09) : 895 - 903
  • [23] Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry
    Lu, Libin
    Yang, Yunjia
    Zhang, Jing
    Shao, Bing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 80 - 85
  • [24] Quantification of bisphenols in Korean urine using online solid-phase extraction-high-performance liquid chromatography-tandem mass spectrometry
    Jo, Min Jeong
    Park, Jae-Hong
    An, Kyung-A
    Choi, Heeju
    Kang, Yun-sook
    Hwang, Myungsil
    ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY, 2020, 80
  • [25] Determination of trace levels of eleven bisphenol A analogues in human blood serum by high performance liquid chromatography-tandem mass spectrometry
    Owczarek, Katarzyna
    Kubica, Pawel
    Kudlak, Blazej
    Rutkowska, Aleksandra
    Konieczna, Aleksandra
    Rachon, Dominik
    Namiesnik, Jacek
    Wasik, Andrzej
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 628-629 : 1362 - 1368
  • [26] Determination of perfluorinated chemicals in food and drinking water using high-flow solid-phase extraction and ultra-high performance liquid chromatography/tandem mass spectrometry
    Chang, Ying-Chia
    Chen, Wen-Ling
    Bai, Fang-Yu
    Chen, Pau-Chung
    Wang, Gen-Shuh
    Chen, Chia-Yang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) : 1315 - 1325
  • [27] Determination of perfluorinated chemicals in food and drinking water using high-flow solid-phase extraction and ultra-high performance liquid chromatography/tandem mass spectrometry
    Ying-Chia Chang
    Wen-Ling Chen
    Fang-Yu Bai
    Pau-Chung Chen
    Gen-Shuh Wang
    Chia-Yang Chen
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1315 - 1325
  • [28] Determination of mitomycin C in rabbit plasma by ultra-high performance liquid chromatography-tandem mass spectrometry
    Tang Yao
    Zhang Shuangqing
    Li Xiang
    Sun Xu
    Wen Nie
    Yu Min
    Peng Lili
    Li Jinrang
    Li Zuogang
    Li Bo
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) : 154 - 159
  • [29] Determination of DCPTA in Mung Bean by Dispersive Solid-Phase Extraction and Ultra-High-Performance Liquid Chromatography–Tandem Mass Spectrometry
    Yuling Gao
    WeiQing Li
    Dongxue Li
    Rui Yan
    Yongxia Guo
    Food Analytical Methods, 2020, 13 : 1666 - 1672
  • [30] Simultaneous determination of parabens, bisphenols and alkylphenols in human placenta by ultra-high performance liquid chromatography-tandem mass spectrometry
    Van Overmeire, Ilse
    Vrijens, Karen
    Nawrot, Tim
    Van Nieuwenhuyse, An
    Van Loco, Joris
    Reyns, Tim
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1121 : 96 - 102