Load following control of pressurized water reactor

被引:0
作者
Lee, Buhm
Park, Young-Hwan
机构
关键词
Load following control; Pressurized water reactor; Self-tuning regulator;
D O I
10.5302/J.ICROS.2008.14.3.221
中图分类号
学科分类号
摘要
This paper presents a self-tuning controller for pressurized water reactor (P.W.R.). This self-tuning controller includes two substantial steps, such as parameter identification and control-law building in each cycle. Extended least square algorithm is used for parameter identification, Kalman filter is used for state estimation, and discrete Riccati equation is used for optimal control. Effectiveness of this algorithm is shown through computer simulation and sensitivity analysis.
引用
收藏
页码:221 / 225
页数:4
相关论文
共 6 条
  • [1] Astrom K.J., Theory and applications of adaptive control-A servey, Automatica, 19, 5, pp. 477-486, (1983)
  • [2] Miller L.F., Et al., Nuclear reactor control systems with sensor failure, Nuclear Technology, 36, pp. 93-195, (1977)
  • [3] Press W.H., Et al., Numerical recipes in C, (1988)
  • [4] Tsay Y.T., Shieh L.S., State-space approach for self-tuning feedback control with pole assignment, IEE Proc, 128, 3, pp. 93-101, (1981)
  • [5] Kirk D.E., Optimal Control Theory: an Introduction, (1970)
  • [6] Shieh L.S., Wang C.T., Tsay Y.T., Fast suboptimal statespace self-tuner for linear stochastic multivariable systems, IEE proc, 130, pp. 143-154, (1983)