Accuracy of the vivofit activity tracker

被引:19
作者
Alsubheen S.A. [1 ]
George A.M. [1 ]
Baker A. [1 ]
Rohr L.E. [1 ]
Basset F.A. [1 ]
机构
[1] School of Human Kinetics and Recreation, Memorial University of Newfoundland, St. John’s
关键词
Energy expenditure; physical activity; step count; treadmill walking test;
D O I
10.1080/03091902.2016.1193238
中图分类号
学科分类号
摘要
The purpose of this study was to examine the accuracy of the vivofit activity tracker in assessing energy expenditure and step count. Thirteen participants wore the vivofit activity tracker for five days. Participants were required to independently perform 1 h of self-selected activity each day of the study. On day four, participants came to the lab to undergo BMR and a treadmill-walking task (TWT). On day five, participants completed 1 h of office-type activities. BMR values estimated by the vivofit were not significantly different from the values measured through indirect calorimetry (IC). The vivofit significantly underestimated EE for treadmill walking, but responded to the differences in the inclination. Vivofit underestimated step count for level walking but provided an accurate estimate for incline walking. There was a strong correlation between EE and the exercise intensity. The vivofit activity tracker is on par with similar devices and can be used to track physical activity. © 2016 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:298 / 306
页数:8
相关论文
共 23 条
[1]  
(2015)
[2]  
Mathers C., Stevens G., Mascarenhas M., Global health risks: mortality and burden of disease attributable to selected major risks, (2009)
[3]  
(2015)
[4]  
Tremblay M.S., Warburton D.E., Janssen I., Et al., New Canadian physical activity guidelines, Appl Physiol Nutr Metab, 36, pp. 36-46, (2011)
[5]  
Fruin M.L., Rankin J.W., Validity of a multi-sensor armband in estimating rest and exercise energy expenditure, Med Sci Sports Exerc, 36, pp. 1063-1069, (2004)
[6]  
Mekky S., (2014)
[7]  
Schneider P.L., Crouter S.E., Lukajic O., Et al., Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk, Med Sci Sports Exerc, 35, pp. 1779-1784, (2003)
[8]  
Mackinlay M.Z., Phases of accuracy diagnosis: visibility of system status in the fitbit, Stanford J Sci Technol Soc, 6, (2013)
[9]  
Crouter S.E., Churilla J.R., Bassett D.R., Estimating energy expenditure using accelerometers, Eur J Appl Physiol, 98, pp. 601-612, (2006)
[10]  
Dannecker K.L., Petro S.A., Melanson E.L., Et al., Accuracy of fitbit activity monitor to predict energy expenditure with and without classification of activities [abstract], Med Sci Sports Exerc, S43, (2011)