Numerical simulation and experimental research on dust concentration distribution in crushing chamber

被引:0
作者
Chen, Jushi [1 ]
Jiang, Zhongan [1 ]
Wang, Ming [1 ]
机构
[1] The Key Laboratory of Ministry of Education for High Efficiency Exploitation and Safety of Metal Mine(University of Science and Technology Beijing), Beijing
来源
Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology | 2015年 / 47卷 / 04期
关键词
Crushing chamber; Dust concentration distribution; Gas-solid two-phase flow; Numerical simulation; Similarity criterion;
D O I
10.11918/j.issn.0367-6234.2015.04.020
中图分类号
学科分类号
摘要
To improve the situation of dust concentration exceeds in crushing chamber and obtain rational parameters for the design of dust removal by ventilation, due to the similarity theory and the motion equations of gas-solid two-phase flow, the similarity index was educed and a similarity model device was designed for the specific situation in the crushing chamber. Furthermore, the dust concentration distribution of similarity model in crushing chamber was simulated by using software named Fluent. After the comparison with similar experimental data analysis, the result showed that the simulation result was consistent with the experimental data. Therefore, the results indicated that dust concentration in chamber under trap wall condition is lower than it under the reflect condition. When the wind velocity at entrance was in the range of 0.2 m/s to 0.5 m/s, dust concentration gradually reduced with the increasement of wind velocity. Finally, after the installation of downdraught dedusting system, the dust concentration was below 2 mg/m3, and the average removal rate reached 90%. ©, 2015, Harbin Institute of Technology. All right reserved.
引用
收藏
页码:115 / 121
页数:6
相关论文
共 4 条
[1]  
Silvester S.A., Lowndes I.S., Kingman S.W., Et al., Improved dust capture methods for crushing plant, Applied Mathematical Modelling, 31, pp. 311-331, (2007)
[2]  
Silvester S.A., The integration of CFD & VR to assist auxiliary ventilation practice, (2002)
[3]  
Posner J.D., Buchanan D., Dunn-Rankin D., Measurement and prediction of indoor air flow in a model room, Energy Build, 35, pp. 515-526, (2003)
[4]  
Lui Z., Wypych P., Cooper P., Dust generation and air entrainment in bulk materials handling-a review, Powder Hand Process, 11, pp. 421-425, (1999)