Three-Dimensional Full-Field Strain Measurements across a Whole Porcine Aorta Subjected to Tensile Loading Using Optical Coherence Tomography–Digital Volume Correlation

被引:0
|
作者
Acosta Santamaría V.A. [1 ,2 ,3 ]
Flechas García M. [1 ,2 ,3 ]
Molimard J. [1 ,2 ,3 ]
Avril S. [1 ,2 ,3 ]
机构
[1] SaInBioSE, INSERM, Saint Etienne
[2] Mines Saint-Etienne, Saint Etienne
[3] Université de Lyon, Saint Etienne
基金
欧洲研究理事会; 欧盟地平线“2020”;
关键词
aortic wall; digital volume correlation; optical coherence tomography; tissue clearing technique; uniaxial tensile test;
D O I
10.3389/fmech.2018.00003
中图分类号
学科分类号
摘要
Optical coherence tomography (OCT) combined with digital volume correlation (DVC) is a suitable technique to investigate the biomechanical behavior of biological tissues at the microscale. However, to characterize the whole thickness of large human or porcine arteries, the use of osmotic tissue clearing agents, such as propylene glycol (PG), is unavoidable due to intrinsic tissue scattering of light. The mechanical response of biological tissues immersed in tissue clearing agents has been poorly investigated so far. Nevertheless, understanding the mechanisms of tissue clearing could be helpful for developing safe optical-clearing methods for possible in vivo applications. The goal of the present work is to combine OCT and DVC to measure displacement and strain fields in porcine aortic tissues immersed in PG and subjected to stress-relaxation uniaxial tension. Displacement and strain fields are measured across the whole thickness of the porcine aortic wall for the first time. Measurement uncertainties and optimal OCT-DVC parameters are determined to define useful technical recommendations for future similar analyses. It is known that the main effect of PG is a significant increase in collagen fibril packing density due to important loss of water (dehydration). It results in a pronounced stiffening of the aortic tensile response when compared to the response of the same tissue immersed in phosphate buffered saline (PBS). This effect is reversible when the aortic tissue is removed from PG polypropylene glycol and immersed again in PBS. Another effect is a dramatic reduction in the Poisson’s effect during tensile loading. But the OCT-DVC-measured strain fields also reveal heterogeneities of this effect among the different layers of the aorta. It appears that the reduced Poisson’s effect is concentrated in the media layer, whereas the adventitia and intima layer keep a usual Poisson’s effect of nearly incompressible tissues. It is concluded that further work should be conducted on how the smooth muscle cells highly present in the media layer are affected by PG polypropylene glycol immersion for a better understanding of these effects. © Copyright © 2018 Acosta Santamaría, Flechas García, Molimard and Avril.
引用
收藏
相关论文
共 50 条
  • [1] Elastic stiffness characterization using three-dimensional full-field deformation obtained with optical coherence tomography and digital volume correlation
    Fu, Jiawei
    Pierron, Fabrice
    Ruiz, Pablo D.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (12)
  • [2] Three-dimensional cellular-level imaging using full-field optical coherence tomography
    Dubois, A
    Moneron, G
    Grieve, K
    Boccara, AC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07): : 1227 - 1234
  • [3] Three-dimensional Full-field Measurements of Large Deformations in Soft Materials Using Confocal Microscopy and Digital Volume Correlation
    C. Franck
    S. Hong
    S. A. Maskarinec
    D. A. Tirrell
    G. Ravichandran
    Experimental Mechanics, 2007, 47 : 427 - 438
  • [4] Three-dimensional full-field measurements of large deformations in soft materials using confocal microscopy and digital volume correlation
    Franck, C.
    Hong, S.
    Maskarinec, S. A.
    Tirrell, D. A.
    Ravichandran, G.
    EXPERIMENTAL MECHANICS, 2007, 47 (03) : 427 - 438
  • [5] Cornea Full-field Displacement and Strain Measurement in Vivo Using Three-dimensional Digital Image Correlation
    Zhang, Xueyong
    Wang, Qing
    Wang, Like
    Xiao, Hong
    Zhang, Daming
    Liao, Rongfeng
    Zheng, Yongping
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (11) : 1027 - 1034
  • [6] Depth-Resolved Full-Field Measurement of Corneal Deformation by Optical Coherence Tomography and Digital Volume Correlation
    J. Fu
    M. Haghighi-Abayneh
    F. Pierron
    P. D. Ruiz
    Experimental Mechanics, 2016, 56 : 1203 - 1217
  • [7] Depth-Resolved Full-Field Measurement of Corneal Deformation by Optical Coherence Tomography and Digital Volume Correlation
    Fu, J.
    Haghighi-Abayneh, M.
    Pierron, F.
    Ruiz, P. D.
    EXPERIMENTAL MECHANICS, 2016, 56 (07) : 1203 - 1217
  • [8] Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation
    Ravindran, Suraj
    Gandhi, Vatsa
    Joshi, Akshay
    Ravichandran, Guruswami
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (02):
  • [9] Full-Field Inspection of a Wind Turbine Blade Using Three-Dimensional Digital Image Correlation
    LeBlanc, Bruce
    Niezrecki, Christopher
    Avitabile, Peter
    Chen, Julie
    Sherwood, James
    Hughes, Scott
    INDUSTRIAL AND COMMERCIAL APPLICATIONS OF SMART STRUCTURES TECHNOLOGIES 2011, 2011, 7979
  • [10] Full-Field Strain Measurements of the Muscle-Tendon Junction Using X-ray Computed Tomography and Digital Volume Correlation
    Iwasaki, Nodoka
    Karali, Aikaterina
    Roldo, Marta
    Blunn, Gordon
    BIOENGINEERING-BASEL, 2024, 11 (02):