Burning behaviour on fire-preventive glued laminated timber of several columns

被引:0
|
作者
Kakae N. [1 ]
Nishimura K. [1 ]
Miyamoto K. [1 ]
Hattori N. [2 ]
Andou K. [2 ]
Harada T. [3 ]
Kamikawa D. [4 ]
Miyabayashi M. [5 ]
机构
[1] Shikoku Research Center of Forestry, Forest Products Research Institute
来源
AIJ Journal of Technology and Design | 2016年 / 22卷 / 52期
关键词
Burning behaviour; Cedar; Column; Fire resistance test; Fire-preventive glued laminated timber; Incising treatment; Larch;
D O I
10.3130/aijt.22.997
中图分类号
学科分类号
摘要
The Japanese government is promoting use of wood in recent years, because of the environmental provision of carbon dioxide fixation. The authors developed "FR wood". "FR wood" is the only technique with simply use one tree species in Japan. "FR wood" is built by three layers. The central member supports load, the second layer prevents a fire and the third layer is surface. A lot of experimental cases were conducted, and many temperature data or carbonization thickness data were accumulated. The measured maximum temperature depended on the thickness and the tree species of load supporting member.
引用
收藏
页码:997 / 1002
页数:5
相关论文
共 50 条
  • [31] Charring behaviour and temperature in the cross section of larch glued laminated timber beams exposed to standard fire heating during the cooling phase
    Kinjo, Hitoshi
    Katakura, Yusuke
    Hirashima, Takeo
    Yusa, Shuitsu
    Bulletin of Japan Association for Fire Science and Engineering, 2016, 66 (01) : 1 - 11
  • [32] Experimental study and theoretical analysis of fire resistance properties of prestressed glued laminated timber beams
    Zhang, Yongwang
    Su, Zheming
    Ni, Weibin
    Zhang, Xiaofei
    Wang, Lu
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 424
  • [33] The charring depth and charring rate of glued laminated timber after a standard fire exposure test
    Yang, Te-Hsin
    Wang, Song-Yung
    Tsai, Ming-Jer
    Lin, Ching-Yuan
    BUILDING AND ENVIRONMENT, 2009, 44 (02) : 231 - 236
  • [34] Assessing the structural behaviour of glued-laminated timber beams using distributed strain sensing
    Goodwin, Jodie
    Woods, Joshua E. E.
    Hoult, Neil A. A.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 325
  • [35] Load carrying behaviour of composite glued laminated timber beams reinforced with fibre reinforced plastics
    Blaß, Hans-Joachim
    Romani, Markus
    Bautechnik, 2002, 79 (04) : 216 - 224
  • [36] The Structural Behaviour of Cross-Laminated Timber Rib Panels in Fire
    Kleinhenz, Miriam
    Just, Alar
    Frangi, Andrea
    FIRE TECHNOLOGY, 2024, 60 (04) : 2651 - 2673
  • [37] FIRE RESISTANCE OF GLUED-LAMINATED TIMBER .2. BENDING PROPERTIES OF BEAMS LAMINATED WITH AQUEOUS POLYMER LSOCYANATE ADHESIVE UNDER FIRE EXPOSURE
    UESUGI, S
    MIYATAKE, A
    KAWAMOTO, N
    MOKUZAI GAKKAISHI, 1993, 39 (10): : 1201 - 1207
  • [38] Experimental investigation into the effect of transparent fireproof coatings on charring behavior of glued laminated timber exposed to fire
    Zheng, Xiuzhi
    He, Minjuan
    Li, Zheng
    Lou, Guobiao
    Li, Guo-Qiang
    FIRE SAFETY JOURNAL, 2024, 150
  • [39] Investigations of the load carrying behaviour of composite glued laminated timber beams reinforced with fiber reinforced plastic
    Blass, HJ
    Romani, M
    HOLZ ALS ROH-UND WERKSTOFF, 2001, 59 (05) : 364 - 373
  • [40] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Joachim Schmid
    Agnese Menis
    Massimo Fragiacomo
    Isaia Clemente
    Giovanna Bochicchio
    Fire Technology, 2015, 51 : 1341 - 1370