Burning behaviour on fire-preventive glued laminated timber of several columns

被引:0
|
作者
Kakae N. [1 ]
Nishimura K. [1 ]
Miyamoto K. [1 ]
Hattori N. [2 ]
Andou K. [2 ]
Harada T. [3 ]
Kamikawa D. [4 ]
Miyabayashi M. [5 ]
机构
[1] Shikoku Research Center of Forestry, Forest Products Research Institute
来源
AIJ Journal of Technology and Design | 2016年 / 22卷 / 52期
关键词
Burning behaviour; Cedar; Column; Fire resistance test; Fire-preventive glued laminated timber; Incising treatment; Larch;
D O I
10.3130/aijt.22.997
中图分类号
学科分类号
摘要
The Japanese government is promoting use of wood in recent years, because of the environmental provision of carbon dioxide fixation. The authors developed "FR wood". "FR wood" is the only technique with simply use one tree species in Japan. "FR wood" is built by three layers. The central member supports load, the second layer prevents a fire and the third layer is surface. A lot of experimental cases were conducted, and many temperature data or carbonization thickness data were accumulated. The measured maximum temperature depended on the thickness and the tree species of load supporting member.
引用
收藏
页码:997 / 1002
页数:5
相关论文
共 50 条
  • [1] INFLUENCE OF FIRE PERFORMANCE MATERIALS AND SCREWS TO FIRE-PREVENTIVE GLUED LAMINATED TIMBER
    Kakae N.
    Sasaki N.
    Miyamoto K.
    AIJ Journal of Technology and Design, 2023, 29 (73) : 1350 - 1355
  • [2] DESIGN OF GLUED LAMINATED TIMBER COLUMNS
    ZAHN, JJ
    RAMMER, DR
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (12): : 1789 - 1794
  • [3] Burning Properties of Combined Glued Laminated Timber
    Kytka, Tomas
    Gasparik, Miroslav
    Novak, David
    Sahula, Lukas
    Karami, Elham
    Das, Sumanta
    FIRE-SWITZERLAND, 2024, 7 (01):
  • [4] A probabilistic approach for the linear behaviour of glued laminated timber
    Kandler, Georg
    Fuessl, Josef
    ENGINEERING STRUCTURES, 2017, 148 : 673 - 685
  • [5] Buckling strength and failure time of Japanese cedar and larch glued laminated timber columns exposed to fire
    Igarashi T.
    Ishii S.
    Yamashita H.
    Baba S.
    Someya T.
    Hirashima T.
    Journal of Structural and Construction Engineering, 2020, 85 (770): : 639 - 649
  • [6] Post-fire structural performance of glued-laminated timber columns subjected to real fires
    Seyedrazavi, Saba
    Viau, Christian
    STRUCTURES, 2025, 75
  • [7] A comparative study of compression behaviors of cross-laminated timber and glued-laminated timber columns
    Wei, Peixing
    Wang, Brad Jianhe
    Li, Hao
    Wang, Libin
    Peng, Si
    Zhang, Long
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 222 : 86 - 95
  • [8] Fire Safety of Glued-Laminated Timber Beams in Bending
    Klippel, Michael
    Frangi, Andrea
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (07)
  • [9] Effect of fire exposure on the mechanical properties of glued laminated timber
    Yang, Te-Hsin
    Wang, Song-Yung
    Tsai, Ming-Jer
    Lin, Ching-Yuan
    Chuang, Ying-Ji
    MATERIALS & DESIGN, 2009, 30 (03) : 698 - 703
  • [10] A Study on the Charring Properties of Glued Laminated Korean Larch Timber Columns
    Choi, Yunjeong
    Baik, Kwonhyuk
    Kim, Suho
    An, Jaehong
    SUSTAINABILITY, 2024, 16 (20)