Demarcated standard and verification of backlash relief in external gear pumps

被引:0
|
作者
Sun F. [1 ]
Li Y. [1 ]
Wen C. [1 ]
Zhong F. [1 ]
机构
[1] School of Mechanical Engineering, Chengdu University, Chengdu
来源
Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering | 2017年 / 33卷 / 20期
关键词
Backlash for connection; Backlash for relief; Demarcated size; Gear pumps; Pumps; Trapped-oil flow rate; Vibrations;
D O I
10.11975/j.issn.1002-6819.2017.20.008
中图分类号
学科分类号
摘要
The gear pumps are used for pumping the working fluid, and its key component is a pair of gear pairs. In the power transmission, the backlash of the gear pair is used to form the lubricating oil film to avoid sticking due to the friction and heat expansion of the gear teeth, but it also affects the stability of the oil film. The choice of backlash in the gear pump is also limited. The backlash of the gear has an influence on the trapped oil performance and volumetric efficiency of the gear pump, while the definition whether there is a backlash existed and the definition what is large backlash and what is small backlash is vague. Based on the common requirements of different backlash values to transmission performance and trapped oil performance, the special trapped-oil circulation and trapped-oil process were analyzed in this study, and the emphasis was on the double teeth meshing range and the single tooth meshing range. From the connection aspect of two different trapped-oil volumes in double teeth meshed range and the improvement aspect of trapped oil performance in single tooth meshed range, we used to separately calculate dynamic trapped-oil flow rate and its maximum value under the two different ranges of double teeth meshing and single tooth meshing, as well as the different formulas to separately calculate dynamic backlash values, its mean value, its lower limiting value used for the connection in double teeth meshed range, and the relief in single tooth meshed range. From such exercises, we derived the definition what was large backlash and what was small backlash. The backlash therefore was defined as, a small backlash was when the backlash value was less than the maximum peak of the backlash for connection, and when the backlash value was greater than the maximum peak of the backlash for connection and less than the maximum peak of the backlash for trapped oil relief, it was a large backlash, and when the backlash value was greater than the maximum peak of the backlash for trapped oil relief, it belonged to the large backlash. An instance of an external gear pump which backlash was 30, 50, 200 μm, was operated and its operation results were analyzed by the theory we developed. The results showed that when the trapped oil flow peak ratio of the unloading area and the connected area was 3, the unloading burden of the former was large. In fact, the really communicating to the communication area required up 2.41 mm backlash, which did not actually exist. So the gear pairs used in gear pumps was the gear pairs with backlash forever. The absolute connection of each other of two different trapped-oil volumes in double teeth meshed range and the absolute trapped-oil relief in single tooth meshed range were nonexistent, but only relatively existed under a certain permission pressure difference. As long as the trapped-oil relief requirement in single tooth meshed range was satisfied by an adopted backlash value, then the connection of two different trapped-oil volumes each other would naturally be met by the adopted backlash value. Backlash for trapped oil relief was larger than the backlash for connection, which can be used in definition what was large backlash and what was small backlash, and the backlash for trapped oil relief can be used as the upper limit. The error in the calculation and experiment was 7.5%, which was reasonable, and the upper limit of the safety margin was 20%, which was reliable. This research provided a reference for distinguishing large backlash between small backlash by Pump backlash defining, and which also provided a theoretical basis for the subsequent studies. © 2017, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
引用
收藏
页码:61 / 66
页数:5
相关论文
共 27 条
  • [1] Li Y., Mechanism, Modeling and Experiment Investigation of Trapped Oil in External Gear Pump, (2009)
  • [2] Yanada H., Ichikawa T., Itsuji Y., Study of the trapping of fluid in a gear pump, Proceedings of the Institution of Mechanical Engineers Part A Journal of Power & Energy, 201, 11, pp. 39-45, (1987)
  • [3] Eaton M., Keogh P.S., Edge K.A., The modelling, prediction, and experimental evaluation of gear pump meshing pressures with particular reference to aero-engine fuel pumps, Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems & Control Engineering, 220, 5, pp. 365-379, (2006)
  • [4] Li Y., Liu C., Wang S., The trapped oil characteristics and flow characteristics with large backlash gap in external gear pumps, Mechanical Science and Technology for Aerospace Engineering, 34, 3, pp. 454-458, (2015)
  • [5] Dalpiaz G., Fernandez Del Rincon A., Mucchi E., Modeling meshing phenomena in gear pumps, Proceedings of ISMA 2004, pp. 949-963, (2004)
  • [6] Eaton M., Keogh P.S., Edge K.A., Modeling and simulation of pressures within the meshing teeth of gear pumps, Proceedings of International Conference on Recent Advances in Aerospace Actuation Systems and Components, (2001)
  • [7] Borghi M., Milani M., Paltrinieri F., Et al., The Influence of Cavitation and Aeration on Gear Pumps and Motors Meshing Volumes Pressures, ASME 2006 International Mechanical Engineering Congress and Exposition, pp. 47-56, (2006)
  • [8] Li Y., Sun F., Quantitative analysis of relationship between backlash value and distance of two relief grooves in external gear pump, Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 28, 22, pp. 63-68, (2012)
  • [9] Li Y., Sun F., Analysis model on trapped oil and backlash calculation in external gear pump, Journal of Drainage and Irrigation Machinery Engineering, 29, 2, pp. 118-122, (2011)
  • [10] Li Y., Accurate calculation of backlash flow in external gear pump, Journal of Drainage and Irrigation Machinery Engineering, 31, 8, pp. 656-661, (2013)