Abatement of amoxicillin and doxycycline in binary and ternary aqueous solutions by gas-phase pulsed corona discharge oxidation

被引:0
|
作者
机构
[1] Sokolov, Alexander
[2] Kråkström, Matilda
[3] Eklund, Patrik
[4] Kronberg, Leif
[5] 1,Louhi-Kultanen, Marjatta
来源
Sokolov, Alexander (alexander.sokolov@lut.fi) | 1600年 / Elsevier B.V., Netherlands卷 / 334期
关键词
Electric corona - Liquid chromatography - Antibiotics - Solutions - Aquatic organisms - Metadata - Alkalinity - Oxidation - Potable water - Energy utilization;
D O I
暂无
中图分类号
学科分类号
摘要
The presence of pharmaceutical compound residues in water bodies is becoming an increasingly serious problem. Various pharmaceuticals have been detected in raw municipal wastewaters, after wastewater treatment plant processes, and even in drinking water. Many common pharmaceuticals are bio-accumulating and they can have a harmful impact on aquatic and terrestrial organisms. In this work, pulsed corona discharge technology (PCD) is studied as a potential method for antibiotic compounds abatement. Two antibiotics, amoxicillin and doxycycline, were chosen as test pharmaceutical compounds. The aim of the study was to investigate the transformation kinetics of binary solutions (water – single antibiotic compound) and ternary solutions (water – two antibiotic compounds) of the compounds and to optimize operational parameters for improved oxidation performance. Ternary solutions were investigated to obtain data on transformation kinetics when two competing pharmaceutical molecules are present in the solution. The experiments showed that reactions of doxycycline oxidation are always first order reactions. Reaction of amoxicillin oxidation has second order in the case of experiments with binary solution in alkaline medium. In other cases, it has first order. The transformation products formed were identified and monitored based on liquid chromatography mass spectrometer analysis. OH-amoxicillin, amoxicillin pencilloic acid, OH-doxycycline and 2-OH-doxycycline had the largest peaks areas. All studied compounds and all transformation products can be easily oxidized by PCD. Approximately 1 kWh/m3 and 0.5 kWh/m3 delivered energy is enough for oxidation of great part of amoxicillin and doxycycline respectively. Low frequency, 50 pps, and high (pH = 12) are preferable for oxidation of both antibiotics from the energy consumption point of view. © 2017 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [1] Abatement of amoxicillin and doxycycline in binary and ternary aqueous solutions by gas-phase pulsed corona discharge oxidation
    Sokolov, Alexander
    Krakstrom, Matilda
    Eklund, Patrik
    Kronberg, Leif
    Louhi-Kultanen, Marjatta
    CHEMICAL ENGINEERING JOURNAL, 2018, 334 : 673 - 681
  • [2] Oxidation of Aqueous Dexamethasone Solution by Gas-Phase Pulsed Corona Discharge
    Onga, Liina
    Kattel-Salusoo, Eneliis
    Trapido, Marina
    Preis, Sergei
    WATER, 2022, 14 (03)
  • [3] Oxidation of Aqueous Naproxen Using Gas-Phase Pulsed Corona Discharge: Impact of Operation Parameters
    Kopecka, Romana
    Onga, Liina
    Preis, Sergei
    WATER, 2022, 14 (20)
  • [4] Oxidation of aqueous organic molecules in gas-phase pulsed corona discharge affected by sodium dodecyl sulphate: Explanation of variability
    Onga, Liina
    Boroznjak, Roman
    Kornev, Iakov
    Preis, Sergei
    JOURNAL OF ELECTROSTATICS, 2021, 111
  • [5] Oxidation of Aqueous Paracetamol by Pulsed Corona Discharge
    Panorel, Iris
    Preis, Sergei
    Kornev, Iakov
    Hatakka, Henry
    Louhi-Kultanen, Marjatta
    OZONE-SCIENCE & ENGINEERING, 2013, 35 (02) : 116 - 124
  • [6] Phenol oxidation in aqueous solution by gas phase corona discharge
    Dors, Miroslaw
    Mizeraczyk, Jerzy
    Mok, Y. S.
    JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2006, 9 (02) : 139 - 143
  • [7] Oxidation of aqueous pharmaceuticals by pulsed corona discharge
    Panorel, Iris
    Preis, Sergei
    Kornev, Iakov
    Hatakka, Henry
    Louhi-Kultanen, Marjatta
    ENVIRONMENTAL TECHNOLOGY, 2013, 34 (07) : 923 - 930
  • [8] Oxidation energy efficiency in water treatment with gas-phase pulsed corona discharge as a function of spray density
    Tikker, P.
    Kornev, I
    Preis, S.
    JOURNAL OF ELECTROSTATICS, 2020, 106
  • [9] Oxidation of Aqueous Toluene by Gas-Phase Pulsed Corona Discharge in Air-Water Mixtures Followed by Photocatalytic Exhaust Air Cleaning
    Kask, Maarja
    Krichevskaya, Marina
    Preis, Sergei
    Bolobajev, Juri
    CATALYSTS, 2021, 11 (05)
  • [10] Non-thermal gas-phase pulsed corona discharge for lignin modification
    Sokolov, Alexander
    Lagerquist, Lucas
    Eklund, Patrik
    Louhi-Kultanen, Marjatta
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2018, 126 : 141 - 149