Research on passive residual heat remove system under loss of power

被引:0
|
作者
Yuan, Tian-Hong [1 ]
Yu, Lei [1 ]
Wang, Chuan [1 ]
机构
[1] Naval University of Engineering, Wuhan 430033, China
来源
关键词
Coolants - Pressurized water reactors - Safety valves - Water levels - Flow of water - Hydraulics - Nuclear fuels - Steam - Nuclear power plants;
D O I
暂无
中图分类号
学科分类号
摘要
The reactor primary cycle and passive core cool system were simulated by use of RELAP5/MOD3.3 code, then we can conclude transient state operating characteristics of AP1000 passive residual heat removal system (PRHRS) under loss of power accident. The results show that: Condition 1, PRHRS starts on low steam generator water level coincident with low start up feed water flow, opening of pressurizer safety valves will lead coolant reverse flow in the PRHRS, and arouse coolant boiling in the core and excessive temperature differentials between inlet outlet of pressure vessel; condition 2, PRHRS starts directly on power loss signal, safety valves will not open before it starts, so PRHRS is capable of operating effectively.
引用
收藏
页码:248 / 252
相关论文
共 50 条
  • [41] Safety margins confidence estimation for a passive residual heat removal system
    Zio, Enrico
    Di Maio, Francesco
    Tong, Jiejuan
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2010, 95 (08) : 828 - 836
  • [42] Steady-state behavior of passive residual heat removal system
    Yan, Chun
    Wang, Jian-Jun
    Yan, Chang-Qi
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (09): : 1071 - 1075
  • [43] Heat loss calculation for premises with passive insolation heating system
    Dusyarov, A.S.
    Applied Solar Energy (English translation of Geliotekhnika), 2002, 38 (04): : 91 - 93
  • [44] Analysis of loss of residual heat removal system for CPR1000 under cold shutdown operation
    Gou, Junli
    Ma, Haifu
    Yang, Zijiang
    Shan, Jianqiang
    ANNALS OF NUCLEAR ENERGY, 2017, 105 : 25 - 35
  • [45] A review on tube external heat transfer for passive residual heat removal heat exchanger in nuclear power plant
    Liu, Yanbin
    Wang, Xuesheng
    Meng, Xiangyu
    Wang, Dawei
    APPLIED THERMAL ENGINEERING, 2019, 149 : 1476 - 1491
  • [46] Test research on special passive safety facility for emergency residual heat removal
    Liu, Xun
    Fu, Liang-Qian
    Xu, Shi-Jie
    Li, Peng-Zhou
    Liu, Xun, 1600, Atomic Energy Press (48): : 1448 - 1453
  • [47] Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Tube outside Boiling Condition
    Liu, Yanbin
    Wang, Xuesheng
    Men, Qiming
    Meng, Xiangyu
    Zhang, Qing
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2017, 2017
  • [48] Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Natural Convection Condition in Tank
    Men, Qiming
    Wang, Xuesheng
    Zhou, Xiang
    Meng, Xiangyu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014
  • [49] Applicability analysis of passive containment heat remove system calculation model based on integrated code
    Zhang, Nan
    Yuan, Shuai
    Xia, Xiang
    Wang, Chang
    Hao, Rui
    ANNALS OF NUCLEAR ENERGY, 2025, 214
  • [50] Transient analysis and optimization of passive residual heat removal heat exchanger in advanced nuclear power plant
    Liu, Yan-Bin
    Meng, Xiang-Yu
    Wang, Xue-Sheng
    Men, Qi-Ming
    Yuan, Yu-Yang
    Cao, Jia-Ming