On-line evaluation method of wind farm off-grid risk in power system stability control

被引:0
|
作者
Li Z. [1 ]
Zhang X. [2 ]
Chen S. [2 ]
Ren Z. [2 ]
Xia S. [2 ]
Wang J. [2 ]
机构
[1] Nanjing Institute of Technology, Nanjing
[2] NR Electric Co., Ltd., Nanjing
基金
中国国家自然科学基金;
关键词
Cut-off strategy; Evaluation criteria; Off-grid risk factor; On-line; Wind farm;
D O I
10.19783/j.cnki.pspc.200634
中图分类号
学科分类号
摘要
Green new energy is developing rapidly, with increasing integration in a clean and efficient wind power industry. However, large-scale off-grid events of wind turbines have occurred from time to time, posing new challenges to the level of control of new energy sources. A method is proposed for an online evaluation criterion for off-grid risk to deal with the difficulty of coordinating the steady-state cut-off strategy with wind power off-grid and the difficulty in judging the off-grid index. Based on the electrical quantity and protection action information of each unit, the risk of an off-network under low-voltage-ride-through mode of wind farm is evaluated taking the wind farm as a whole. The method realizes panoramic monitoring and evaluation of the wind farm fault process, laying the foundation for precise control and cut-off execution. Finally, the effectiveness of the proposed de-networking risk assessment criteria is verified by simulation. © 2020, Power System Protection and Control Press. All right reserved.
引用
收藏
页码:162 / 169
页数:7
相关论文
共 28 条
  • [1] REN Zuyi, ZHAO Mingjun, XIA Shangxue, Et al., Application of wide area protection and control system to Southern Xinjiang Power Grid, Automation of Electric Power Systems, 32, 12, pp. 104-107, (2008)
  • [2] XUE L, XIONG Z, LEI W, Et al., Transmission line over-load risk assessment for power systems with wind and load-power generation correlation, IEEE Transactions on Smart Grid, 6, 3, pp. 1233-1242, (2015)
  • [3] CHEN Qing, SHAN Xin, LUO Jianyu, Source-grid-load coordinated control strategy and its application under UHVDC faults, Automation of Electric Power Systems, 41, 5, pp. 147-151, (2017)
  • [4] BI Pingping, XU Xiaoyan, MEI Wenming, Et al., Study on cascaded tripping-off risk assessment method and delivery capacity of wind power base, Power System Technology, 43, 3, pp. 903-910, (2019)
  • [5] LIU Wenying, YANG Nan, ZHANG Jianli, Et al., Complex grid failure propagating chain model in consideration of adverse weather, Proceedings of the CSEE, 32, 7, pp. 53-59, (2012)
  • [6] ZHOU Hongting, XIE Huan, WU Tao, Et al., Analysis and simulation of wind farm dynamic behavior in high-voltage trip-off accident of Zhangbei, Electric Power Automation Equipment, 37, 2, pp. 54-60, (2017)
  • [7] LITTLER T, CHEN Linyu, LITTLER T, HAN Shushan, Et al., Risk assessment model for wind generator tripping off, Proceedings of the CSEE, 35, 3, pp. 576-582, (2015)
  • [8] MENSOUL S, ESSADKI A, NASSER T, Et al., A direct power control of a DFIG based WECS during symmetrical voltage dips, Protection and Control of Modern Power Systems, 5, 1, pp. 36-47, (2020)
  • [9] TANG Y, HE H, WEN J, Et al., Power system stability control for a wind farm based on adaptive dynamic programming, IEEE Transactions on Smart Grid, 6, 1, pp. 166-177, (2017)
  • [10] HAN Pingping, CHEN Lingqi, HU Di, Et al., Impact of transient overvoltage caused by DC block on wind power transmission and its suppression measure, Power System Protection and Control, 46, 5, pp. 99-105, (2018)