A survey of fault location on transmission line based on synchronized phasor measurement technique

被引:0
|
作者
Wang, Bo [1 ]
Wang, Wei [2 ]
Chen, Chao [1 ]
机构
[1] College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
[2] Zhejiang Electric Power Corporation, Hangzhou 310007, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
47
引用
收藏
页码:122 / 128
相关论文
共 50 条
  • [1] Analysis of Fault Location Algorithm for Transmission Line Protection Based on Synchronized Phasor Measurement
    Muddebihalkar, Sunita V.
    Jadhav, Ganesh N.
    2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 118 - 123
  • [2] Fault Location Scheme on a Three Phase Transmission Line using Synchronized Phasor Measurement
    Anees, Ahmed Sharique
    Jamil, Majid
    Rizwan, M.
    2012 IEEE 5TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE 2012), 2012,
  • [3] A current independent synchronized phasor measurement based method for fault location on transmission lines
    Firouzjah, K. G.
    Sheikholeslami, A.
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, 2007, : 304 - 308
  • [4] Iterative Fault Location Scheme for a Transmission Line Using Synchronized Phasor Measurements
    Brahma, Sukumar M.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2007, 8 (06):
  • [5] Fault Location Diagnosis Based In Synchronized Phasor Measurements
    Gonzalez, C.
    Vazquez, E.
    Sellschopp, F.
    IEEE LATIN AMERICA TRANSACTIONS, 2015, 13 (03) : 645 - 650
  • [6] A Novel Approach for Transmission Line Fault Location using Synchro Phasor Measurement
    Lohith, M.
    Babu, P. Suresh
    Roy, Saptarshi
    Reddy, K. V. Ramana
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [7] An effective fault location technique for transmission grids using phasor measurement units
    Jiang, Zhen
    Miao, Shihong
    Xu, Hao
    Liu, Pei
    Zhang, Buhan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 653 - 660
  • [8] New fault-location method for a single multiterminal transmission line using synchronized phasor measurements
    Brahma, Sukumar M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1148 - 1153
  • [9] New fault location scheme for a two-terminal transmission line using synchronized phasor measurements
    Brahma, S. M.
    2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, : 853 - 857
  • [10] Phasor-measurement-unit-based transmission line fault location estimator under dynamic conditions
    He, Z. Y.
    Mai, R. K.
    He, W.
    Qian, Q. Q.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (11) : 1183 - 1191